‹ Vorheriger
zurück zur Liste
30 von 22699
Nächster ›

Zugriffsnummer 56760
Dokumenttyp Dissertation Open Access Gold
Sprache Englisch
Titel Searching for variations of fundamental constants and ultralight dark matter with optical clocks
Autor(in); Institution
Filzinger, Melina; 4.4, Zeit und Frequenz, PTB-Braunschweig
Quelle/Jahr (2026), 149 S.
Schriftenreihe PTB-Bericht PTB-Diss-27
Dissertationsvermerk Dissertation, Gottfried Wilhelm Leibniz Universität Hannover, 2025
ISSN 2941-1297
ISBN 978-3-944659-59-6
DOI
Berichtsnummer PTB-Diss-27
Verlag Braunschweig: Physikalisch-Technische Bundesanstalt (PTB)
Freie Schlagworte optical atomic clocks ; searches for new physics ; ultralight dark matter
Zusammenfassung This thesis reports on frequency comparisons with optical clocks based on trapped ions, and their application to probing variations of fundamental constants, with a focus on searches for ultralight dark matter (UDM). The work was carried out at the Physikalisch-Technische Bundesanstalt (PTB). An existing optical clock based on a single 171Yb+ ion is operated with high availability over several years. Two atomic transitions are probed in an interleaved fashion: An electric octupole (E3) transition, which is highly sensitive to possible variations of the fine-structure constant, and an electric quadrupole (E2) transition. Including the resulting measurement data with that previously obtained in our group further improves the best constraints on a linear drift of the fine-structure constant α to (1/α)(dα/dt)=1.8(2.5)×10−19/yr, and its coupling to the gravitational potential Φ of the sun to (c2/α)(dα/dΦ)=−2.4(3.0)×10−9, reducing uncertainties by about a factor of four. The same data, along with that from a comparison between the 171Yb+ E3 clock and a Sr lattice clock, is analysed for the oscillatory signatures associated with small hypothetical couplings between UDM and normal matter. Leveraging the high α-sensitivity of both frequency ratios, more than an order-of-magnitude improvement in limits on a scalar UDM coupling to photons is achieved over a wide range of dark matter masses. UDM couplings to the nuclear sector are investigated with optical clocks for the first time, by considering the effect an oscillating nuclear charge radius would have on the E3/E2 frequency ratio. It is further demonstrated that space- and time-separated clock comparisons provide sensitivity to dark matter even for oscillators with identical sensitivities to fundamental constants, while also offering access to unique dark matter signatures and complementary UDM couplings. A new dual-species apparatus for combining 171Yb+ and 88Sr+ ions enables the realization of a multi-ion clock based on the 2S1/2→2D5/2 transition in 88Sr+ with up to ten ions. A fractional systematic uncertainty of 5.3×10−19 is obtained for the multi-ion clock, comparable to the current best single-ion clocks. A frequency comparison between the new optical clock based on 88Sr+ and the single-ion 171Yb+ clock operating on the 2S1/2 (F=0)→2F7/2 (F=3) E3 transition yields an unperturbed frequency ratio of 0.6926711632159660399(20). With a fractional uncertainty of 2.9×10−18, this is the most accurate determination of any physical constant to date. The data obtained with multiple 88Sr+ ions is compatible with that obtained using a single 88Sr+ ion, but offers a significantly improved instability. This establishes multi-ion clocks as a robust platform for next-generation tests of fundamental physics.
Kostenfreier Zugang Open Access Gold

Zitierung

Filzinger, M. (2026). Searching for variations of fundamental constants and ultralight dark matter with optical clocks [Dissertation, Gottfried Wilhelm Leibniz Universität Hannover, 2025]. Braunschweig: Physikalisch-Technische Bundesanstalt (PTB). https://doi.org/10.7795/110.20260227

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag