Zugriffsnummer 56201
Dokumenttyp Zeitschriftenartikel Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel High-stability optical clock based on a continuously ground-state cooled Al+ion without compromising its accuracy
Autor(in); Institution
Dawel, Fabian; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig
Pelzer, Lennart; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig
Dietze, Kai; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig
Kramer, Johannes; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig
Hild, Marek; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig
King, Steven A.; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig
Spethmann, Nicolas C. H.; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig ; formerly
Klose, Joshua; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Stahl, Kilian; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Dörscher, Sören; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Benkler, Erik; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Lisdat, Christian; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Porsev, Sergey G.; Department of Physics and Astronomy, University of Delaware, Newark, Delaware, USA
Safronova, Marianna S.; Department of Physics and Astronomy, University of Delaware, Newark, Delaware, USA
Schmidt, Piet O.; QUEST Institute for Experimental Quantum Metrology, PTB-Braunschweig; Leibniz Universität Hannover, Institut für Quantenoptik, Hannover, GERMANY
Quelle/Jahr Physical Review Research: 8 (2026), 2, 1 - 11
Artikelnummer 023327
Availability [online only]
ISSN 2643-1564 (online)
DOI
Verlag College Park, Md.: American Physical Society (APS)
Freie Schlagworte Optical clock ; Sympathetic colling ; ac-Stark shift ; Time-dilation shift
Zusammenfassung Single-ion optical clocks have shown systematic frequency uncertainties below 10−18, but typically require more than one week of averaging to achieve a corresponding statistical uncertainty. This time can be reduced with longer probe times, but comes at the cost of a higher time-dilation shift due to motional heating of the ions in the trap. We show that sympathetic ground-state cooling using electromagnetically induced transparency of an Al+ clock ion via a cotrapped Ca+ ion during clock interrogation suppresses the heating of the ions. Al+ can be kept close to the motional ground state, independent from the chosen interrogation time, at a relative time-dilation shift of (−1.69±0.20)×10−18. The Ca+ cooling light introduces an additional light shift on the Al+ clock transition of (−9.3±1.1)×10−18. We project that the uncertainty of this light shift can be further reduced by nearly an order of magnitude. This sympathetic cooling enables seconds of interrogation time with 10−19 motional and cooling laser-induced uncertainties for Al+ and can be employed in other ion clocks as well.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Zeit und Frequenz
Innovationscluster Quantentechnologie
Geschäftsfelder Grundlagen der Metrologie
Förderinformationen (1) Förderername: Deutsche Forschungsgemeinschaft (DFG)
Förderer ID:  0000 0001 2096 9829
Förderer ID Typ: ISNI
Förderprogramm: Germany's Excellence Strategy - EXC- 2123 QuantumFrontiers
Titel der Förderung: EXC 2123 - Quantum Frontiers
Förderungsnummer: 390837967
Förderinformationen (2) Förderername: Deutsche Forschungsgemeinschaft (DFG)
Förderer ID: 0000 0001 2096 9829
Förderer ID Typ: ISNI
Titel der Förderung: SFB 1227 DQ-mat
Förderungsnummer: 274200144
Förderinformationen (3) Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989
Förderer ID Typ: ISNI
Förderprogramm: Horizon 2020 Research and Innovation program
Titel der Förderung: 20FUN01: TSCAC: Two-species composite atomic clocks
Förderungsnummer: 20FUN01
Förderinformationen (4) Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989
Förderer ID Typ: ISNI
Förderprogramm: Horizon 2020 Research and Innovation program
Förderungsnummer: 101019987
Förderinformationen (5) Förderername: Bundesministerium für Forschung, Technologie und Raumfahrt
Förderer ID: 0000 0001 0860 4501
Förderer ID Typ: ISNI
Förderprogramm: Clusters4Future
Titel der Förderung: QVLS-iLabs
Förderungsnummer:  03ZU1209EE
Förderinformationen (6) Förderername: U. S. Office of Naval Research
Förderungsnummer:  N000142512105
Förderinformationen (7) Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989
Förderer ID Typ: ISNI
Förderprogramm: EPM 2023 Fundamental
Titel der Förderung: 23FUN03: HIOC: High-accuracy ion-based optical clocks
Förderungsnummer: 23FUN03

Zitierung

Dawel, F., Pelzer, L., Dietze, K., Kramer, J., Hild, M., King, S. A., Spethmann, N. C. H., Klose, J., Stahl, K., Dörscher, S., Benkler, E., Lisdat, C., Porsev, S. G., Safronova, M. S., & Schmidt, P. O. (2026). High-stability optical clock based on a continuously ground-state cooled Al⁺ion without compromising its accuracy. Physical Review Research, 8(2), 1–11. https://doi.org/10.1103/48zr-2t1p

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag