Autor(in); Institution
van der Heide, Oscar; Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, THE NETHERLANDS
Versteeg, Edwin; Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, THE NETHERLANDS
Kuijer, Joost; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, THE NETHERLANDS
Schilder, Martin B.; Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, THE NETHERLANDS
Kolbitsch, Christoph; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Keil, Vera C.; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, THE NETHERLANDS
van den Berg, Cornelis A.; Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, THE NETHERLANDS
Sbrizzi, Alessandro A.; Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy, University Medical Center Utrecht, Utrecht, THE NETHERLANDS
Quelle/Jahr Proceedings of the International Society for Magnetic Resonance in Medicine:(2026), 1 - 3
Availability [online only]
ISSN 1065-9889 (online)
URL
Verlag ISMRM
Konferenzangaben Annual Meeting of the ISMRM, Capetown, 9-14, Mai, 2026, South Africa
Freie Schlagworte Quantitative Imaging ; Open-source Software ; MR-STAT ; Pulseq
Zusammenfassung Motivation: The clinical translation of fast quantitative MRI is limited by vendor-specific sequences, hindering standardized data acquisition in multi center studies. Goals: To develop and validate a vendor-agnostic 3D MR-STAT pulse sequence for rapid, high-resolution T1, T2, and proton density mapping. Approach: A 3D MR-STAT sequence was implemented in Pulseq and executed on a Siemens 3T scanner for quantitative brain imaging of a healthy volunteer. Results: The Pulseq sequence ran successfully, yielding high-quality, 1mm isotropic T1, T2, and PD maps in 3.5 minutes. Mean gray/white matter values were consistent with established findings, demonstrating the fidelity of this vendor-neutral implementation.