Zugriffsnummer 54821
Dokumenttyp Zeitschriftenartikel
Peer Review mit Peer Review
Sprache Englisch
Titel Secondary flows drive triboelectric powder charging in pneumatic conveying
Autor(in); Institution
Özler, Gizem; 3.5, Explosionsschutz in der Energietechnik, PTB-Braunschweig
Grosshans, Holger; 3.5, Explosionsschutz in der Energietechnik, PTB-Braunschweig
Quelle/Jahr Journal of Fluid Mechanics: 1007 (2025), A52, 1 - 28
ISSN 0022-1120 (print) ; 1469-7645 (online)
DOI
URL
Verlag Cambridge: Cambridge University Press
Zusammenfassung Highly resolved simulations reveal the fundamental influence of a carrier fluid’s flow dynamics on triboelectric powder charging. We found that particles transported through a square-shaped duct charge faster than in a channel flow caused by secondary flows that led to more severe particle–wall collisions. Specifically, particles with a Stokes number of 4.69 achieve 85 % of their equilibrium charge approximately 1.5 times faster in duct flow than in channel flow. Also, charge distribution is more uniform in a duct cross-section compared with a channel cross-section. In channel flow, particles are trapped near the walls and collide frequently due to limited movement in the wall-normal direction, causing localized charge buildup. In contrast, duct flow promotes better mixing through secondary flows, reducing repeating collisions and providing uniform charge distribution across the cross-section. Upon charging, electrostatic forces significantly reshape particle behaviour and distribution. Once the powder achieves half of its equilibrium charge, particles increasingly accumulate at the wall, leading to a reduced concentration in the central region. These changes in particle distribution have a noticeable impact on the surrounding fluid phase and alter the overall flow dynamics. These findings open the possibility for a new measure to control powder charging by imposing a specific pattern.
Themenbereich der Metrologie Physikalische Sicherheitstechnik, Explosionsschutz
Innovationscluster Energie
Forschungsprojekt PowFEct
Förderinformationen (1) Förderername: European Research Council (ERC)
Förderer ID: 0000 0000 8923 0953
Förderer ID Typ: ISNI
Titel der Förderung: PowFEct
Förderungsnummer: 947606
URI der Förderung: https://cordis.europa.eu/project/id/947606/de

Zitierung

Özler, G. & Grosshans, H. (2025). Secondary flows drive triboelectric powder charging in pneumatic conveying. Journal of Fluid Mechanics, 1007(A52), 1–28. https://doi.org/10.1017/jfm.2025.99