Zugriffsnummer 54565
Dokumenttyp Konferenzartikel
Peer Review mit Peer Review
Sprache Englisch
Titel REMINISCE: refurbishment of mirrors to increase sustainability at light sources
Autor(in); Institution
Schmidtchen, Silja; European XFEL GmbH, Schenefeld, GERMANY
Siewert, Frank; Helmholtz Zentrum Berlin, Berlin, GERMANY
Barrett, Ray; European Synchrotron Radiation Facility, Grenoble, FRANCE
Alcock, Simon G.; Diamond Light Source Ltd., Didcot, UK
Dennetiere, David; Société civile Synchrotron SOLEIL, FRANCE
Bagschik, Kai; Deutsches Elektronen-Synchrotron, Hamburg, GERMANY
Totani, Roberta; Elettra - Sincrotrone Trieste S.C.p.A., Triest, ITALY
Wagner, Ulrich; Paul Scherrer Institut PSI, Würenlingen, SWITZERLAND
Störmer, Michael; Helmholtz-Zentrum Hereon, GERMANY
Fernandez Herrero, Analia; 7.1, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Heinis, Dominique; ALBA Synchrotron, Barcelona, SPAIN
Pickworth, Louisa; MAX IV Lab., Lund, SWEDEN
Quelle/Jahr Optics Damage and Materials Processing by EUV/X-ray Radiation (XDam9):(2025), 1353306-1 - 1353306-9
Artikelnummer 1353306
Schriftenreihe Proceedings of SPIE: 13533
Herausgeber(in)
Juha, Libor; Institute of Physics of the ASCR, CZECH REPUBLIC
Bajt, Sasa; Deutsches Elektronen-Synchrotron, Hamburg, GERMANY
Guizard, Stéphane; CEA-DRF-IRAMIS, Lab. des Solides Irradiés, FRANCE
ISSN 0277-786X
DOI
Verlag Bellingham, Wash.: SPIE
Konferenzangaben SPIE Optics + Optoelectronics, Prague, 3, Juni, 2025, Tschechien
Freie Schlagworte Contamination ; Mirrors ; Coating ; Optical surfaces ; X-ray optics ; Light sources ; Mirror surfaces ; X-rays Metrology ; Plasma
Zusammenfassung Contamination or damage to X-ray optics is becoming increasingly problematic for beamlines at 3rd and 4th generation storage-rings and FEL sources. Carbon contamination, induced by ultra-intense photon-beams, can cause a major loss in flux, focusing power, and specific absorptions which are detrimental to spectroscopy. For new light sources, with higher coherence, intensity, and repetition rates, contamination and accumulated damage will occur more rapidly. Replacing damaged optics is a time-consuming, risky, and expensive task. Production times are typically >6 months, and sometimes exceed 1 year. Costs per optic are typically tens of thousands of Euro, and can exceed 100k Euro. If several optics need to be replaced on a beamline, the overall cost can be hundreds of thousands of Euros. It is not sustainable or cost effective to replace optics on a yearly basis. Most facilities have independently investigated optical contamination over many years, but coordinated action is now required before the problem gets out of control. These issues motivate two-fold action: find practical methods to slow down the rate of contamination and damage; and develop protocols to safely remove contamination and return the optic to a pristine condition. High-quality metrology and surface science techniques are required to quantify the topography and chemical nature of the contamination, and assess the effectiveness of methods to reduce or remove it. To achieve these challenging goals requires a community effort. We propose an extensive collaboration, including experts from a range of scientific disciplines at various synchrotron and XFEL labs. X-ray optic community projects have recently delivered improvements in the quality X-ray mirrors via enhanced optical metrology. It is hoped that a concerted group effort will deliver similar major advancements, thereby helping to provide beamlines with cleaner, better-performing, X-ray optics.
Themenbereich der Metrologie Photometrie und Radiometrie

Zitierung

Schmidtchen, S., Siewert, F., Barrett, R., Alcock, S. G., Dennetiere, D., Bagschik, K., Totani, R., Wagner, U., Störmer, M., Fernandez Herrero, A., Heinis, D., & Pickworth, L. (2025). REMINISCE: refurbishment of mirrors to increase sustainability at light sources. SPIE Optics + Optoelectronics, Prague, 3, Juni, 2025, Tschechien. https://doi.org/10.1117/12.3056261

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag