Titel Temperature dependence of the sensitivity of hydrophones for biomedical ultrasound exposimetry
Autor(in); Institution
Wilkens, Volker; 1.6, Schall, PTB-Braunschweig
Weber, Martin; University of Helsinki, Helsinki, FINLAND
Twiefel, Jennifer; 1.6, Schall, PTB-Braunschweig
Quelle/Jahr IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control: 72 (2025), 3, 362 - 369
ISSN 0885-3010 (print) ; 1525-8955 (online)
DOI
URL
Verlag Piscataway, NJ: IEEE
Freie Schlagworte acoustic output ; acoustic pressure measurement ; calibration ; exposimetry ; hydrophone
Zusammenfassung Though it has been recognized that the sensitivity of hydrophones depends on the temperature of the water they are used in, the amount of specific data that is available is very limited. This is possible because the measurements are technically challenging, laborious, and time-consuming. A broadband primary hydrophone calibration setup was extended to implement stable calibration conditions at different temperature settings. Four hydrophones of different types commonly used in ultrasound exposimetry were then characterized in the range from 17 °C to 29 °C, and average change rates of the sensitivity with temperature were determined for different ultrasonic frequencies. Two different membrane hydrophones showed an increase in sensitivity with increasing temperature in the range from 0.55% to 1.10% per 1 °C temperature rise within their bandwidths. The results for a capsule-type and a needle-type hydrophone were different in the sense that a decreasing sensitivity with increasing temperature was also observed. For the capsule-type hydrophone, a small increase was observed up to 15 MHz and a decrease for higher frequencies. The needle-type hydrophone provided a decrease at all frequencies, and the results were more noisy. Data, as determined in this study, can be applied to correct acoustic output measurements of medical ultrasonic equipment if the water temperature of the hydrophone application differs from that during calibration. Alternatively, it may suffice in some applications to consider a sensitivity change with temperature within the uncertainty estimation of the exposure measurement, in particular, if the temperature difference is limited to 1 °C or 2 °C.
Themenbereich der Metrologie Akustik, Ultraschall, Beschleunigung
Geschäftsfelder Metrologie für die Gesellschaft ; Metrologie für die Wirtschaft
Forschungsprojekt Sekundäres Impulskalibriersystem für Ultraschallhydrophone
Förderinformationen (1) Förderername: Bundesministerium für Wirtschaft und Energie (BMWi)
Förderer ID: 0000 0001 1092 3392
Förderer ID Typ: ISNI
Förderprogramm: TransMeT 2019-1_2
Titel der Förderung: Sekundäres Impulskalibriersystem für Ultraschallhydrophone

Zitierung

Wilkens, V., Weber, M., & Twiefel, J. (2025). Temperature dependence of the sensitivity of hydrophones for biomedical ultrasound exposimetry. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 72(3), 362–369. https://doi.org/10.1109/TUFFC.2025.3527625