Zugriffsnummer 53286
Dokumenttyp Zeitschriftenartikel
Peer Review mit Peer Review
Sprache Englisch
Titel EURAMET.T-K9 regional key comparison ITS-90 SPRT calibration from the Ar TP to the Zn FP (Final report)
Autor(in); Institution
Sparasci, Fernando; Laboratoire National et d'Essais, National des Arts et Métiers (LNE-Cnam), Paris, FRANCE
Risegari, Lara; Laboratoire National et d'Essais, National des Arts et Métiers (LNE-Cnam), Paris, FRANCE
Martin, Catherine; Laboratoire National et d'Essais, National des Arts et Métiers (LNE-Cnam), Paris, FRANCE
Hermier, Yves; Laboratoire National et d'Essais, National des Arts et Métiers (LNE-Cnam), Paris, FRANCE
Lopardo, Giuseppina; Instituto Nazionale di Ricercha Metrologica (INRiM), Torino, ITALY
Steur, Petrus Paulus Maria; Instituto Nazionale di Ricercha Metrologica (INRiM), Torino, ITALY
Pearce, Jonathan; National Physical Laboratory (NPL), Teddington, UNITED KINGDOM
Bünger, Lars; 7.4, Temperatur, PTB-Berlin
Rudtsch, Steffen; 7.4, Temperatur, PTB-Berlin
Bruin‑Barendregt, Conny de; Van Swinden Laboratorium (VSL), Delft, THE NETHERLANDS
Panman, Matthijs; Van Swinden Laboratorium (VSL), Delft, THE NETHERLANDS
Peruzzi, Andrea; Former VSL researcher
Hofstätter-Mohler, Christina; Bundesamt für Eich- und Vermessungswesen (BEV), Wien, AUSTRIA
Turzó-András, Emese; Budapest Fövaros Kormanyhivatala (BFKH), Budapest, HUNGARY
Nedialkov, Sasho; Bulgarian Institute of Metrology (BIM), Sofia, BULGARIA
Spasova, Snezhana; Bulgarian Institute of Metrology (BIM), Sofia, BULGARIA
Petrusova, Olgica; Bureau of Metrology (BoM), Skopje, NORTH MACEDONIA
Hernandez, Maria Jose Martin; Centro Espanol de Metrologia (CEM), Tres Cantos, SPAIN
Maldonado, Dolores des Campo; Centro Espanol de Metrologia (CEM), Tres Cantos, SPAIN
Izquierdo, Carmen Garcia; Centro Espanol de Metrologia (CEM), Tres Cantos, SPAIN
Strnad, Radek; Czech Metrology Institute (CMI), Brno, CZECHIA
Simic, Slavica; Directorate of Measures and Precious Metals (DMDM), Beograd, SERBIA
Stepanovic, Vladan; Directorate of Measures and Precious Metals (DMDM), Beograd, SERBIA
Nielsen, Jan; Danisch Technological Institute (DTI), Aarhus, DENMARK
Kokkini, Evmorfia; Hellenic Institute of Metrology (EIM), Thessaloniki, GREECE
Gaidamoviciute, Lilijana; Fizniu ir technologijos mokslu centras (FTMC), Vilnius, LITHUANIA
Galkauskas, Linas; Fizniu ir technologijos mokslu centras (FTMC), Vilnius, LITHUANIA
Mikalauskas, Kestutis; Fizniu ir technologijos mokslu centras (FTMC), Vilnius, LITHUANIA
Kozicki, Marek; Physical Chemistry Division, Central Office of Measures (GUM), Warsawa, POLAND
Zvizdic, Davor; Laboratory for Process Measurement (FSB-LPM), Zagreb, CROATIA
Sestan, Danijel; Laboratory for Process Measurement (FSB-LPM), Zagreb, CROATIA
Mutapcic, Nedzadeta; Institut Metrology Bosnia and Herzegovina (IMBiH), Sarajevo, BOSNIA AND HERZEGOVINA
Stratulat, Camelia; National Institut of Metrology (INM-RO), Bucuresti, ROMANIA
Neagu, Marius Dumitru; National Institut of Metrology (INM-RO), Bucuresti, ROMANIA
Eusebio, Liliana; Instituto Portogues da Qualidade (IPQ), Caparica, PORTUGAL
Olsen, Age Andreas Falnes; Justervesenet (JV), Kjeller, NORWAY
Opel, Karsten; Justervesenet (JV), Kjeller, NORWAY
Kvernmo, Gjermund; Justervesenet (JV), Kjeller, NORWAY
Högström, Richard; Valtion teknilinen tutkimuskeskus Mittatekniikan Keskus (VTT MIKES), Espoo, FINLAND
Heinonen, Martti; Valtion teknilinen tutkimuskeskus Mittatekniikan Keskus (VTT MIKES), Espoo, FINLAND
Bojkovski, Jovan; Metrology Institute of the Republic of Slovenia/ University of Ljubljana - Faculty of Electrical Engineering/ Laboratory of Metrology and Quality (MIRS/ UL-FE/ LMK), Ljubljana, SLOVENIA
Zuzek, Vincencij; Metrology Institute of the Republic of Slovenia/ University of Ljubljana - Faculty of Electrical Engineering/ Laboratory of Metrology and Quality (MIRS/ UL-FE/ LMK), Ljubljana, SLOVENIA
MacLochlainn, Dubhaltach; National Standards Authority of Ireland, National Metrology Laboratory (NSAI-NML), Dublin, IRELAND
Holmsten, Magnus; Research Institutes of Sweden (RISE), Boras, SWEDEN
Senn, Remo; Swiss Federal Office of Metrology and Accreditation (METAS), Bern-Wabern, SWITZERLAND
Dobre, Miruna; Service de la Métrologie (SMD), Brussels, BELGIUM
Pavlasek, Peter; Slovensky Metrologicky ustav (SMU), Bratislava, SLOVAKIA
Kalemci, Murat; Turkiye Bilimsel ve Teknolojik Arastirma Kurumu/ Ulusal Metroloji Enstitüsü (TÜBITAK/ UME), Gebze-Kocaeli, TÜRKIYE
Quelle/Jahr Metrologia: 61 (2024), 199 S.
ISSN 0026-1394
DOI
Verlag Bristol: IOP Publishing
Zusammenfassung This is a report to the Technical Committee for Thermometry of EURAMET (EURAMET TC-T) on the regional key comparison EURAMET.T-K9 of SPRT calibration on the International Temperature Scale of 1990 (ITS-90), from 83.8058 K (the Ar triple point) to 692.677 K (the Zn fixed point). The transfer standards used are long-stem SPRTs. EURAMET.T-K9 is an RMO key comparison linked to the CIPM key comparison CCT-K9. The comparison is organized in five separate collapsed Stars, each one having a CCT-K9 participant as pilot, which provides the link to the KCRV of CCT-K9. Four to five participating laboratories are involved in each Star. The pilots of the five Stars are LNE-Cnam, PTB, INRiM, VSL, NPL. LNE-Cnam is also the coordinator of the comparison, in charge of the collection of the measurement reports from all participants and the preparation of the final report.

Zitierung

Sparasci, F., Risegari, L., Martin, C., Hermier, Y., Lopardo, G., Steur, P. P. M., Pearce, J., Bünger, L., Rudtsch, S., Bruin‑Barendregt, C. D., Panman, M., Peruzzi, A., Hofstätter-Mohler, C., Turzó-András, E., Nedialkov, S., Spasova, S., Petrusova, O., Hernandez, M. J. M., Maldonado, D. D. C., Izquierdo, C. G., Strnad, R., Simic, S., Stepanovic, V., Nielsen, J., Kokkini, E., Gaidamoviciute, L., Galkauskas, L., Mikalauskas, K., Kozicki, M., Zvizdic, D., Sestan, D., Mutapcic, N., Stratulat, C., Neagu, M. D., Eusebio, L., Olsen, A. A. F., Opel, K., Kvernmo, G., Högström, R., Heinonen, M., Bojkovski, J., Zuzek, V., MacLochlainn, D., Holmsten, M., Senn, R., Dobre, M., Pavlasek, P., & Kalemci, M. (2024). EURAMET.T-K9 regional key comparison ITS-90 SPRT calibration from the Ar TP to the Zn FP (Final report). Metrologia, 61, 199 S. https://doi.org/10.1088/0026-1394/61/1A/03005

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag