Zugriffsnummer 53285
Dokumenttyp Zeitschriftenartikel
Peer Review mit Peer Review
Sprache Englisch
Titel Key Comparison CCT-K9 : ITS-90 SPRT calibration from the Ar TP to the Zn FP
Autor(in); Institution
Herman, Tobias; National Institute of Standards and Technology (NIST), Gaithersburg, USA
Chojnacky, Michael; National Institute of Standards and Technology (NIST), Gaithersburg, USA
Hill, Ken; National Research Council of Canada (NRC), Ottawa, CANADA
Rudtsch, Steffen; 7.4, Temperatur, PTB-Berlin
Yang, Inseok; Korea Research Institute of Standards and Science (KRISS), Daejeon, Republic of KOREA
Steur, Peter P.; Istituto Nazionale di Ricerca Metrologica (INRiM), Torino, ITALY
Dematteis, Roberto; Istituto Nazionale di Ricerca Metrologica (INRiM), Torino, ITALY
Lopardo, Giuseppina; Istituto Nazionale di Ricerca Metrologica (INRiM), Torino, ITALY
Sparasci, Fernando; Laboratoire National et d'Essais, National des Arts et Métiers (LNE-Cnam), Paris, FRANCE
Martin, Catherine; Laboratoire National et d'Essais, National des Arts et Métiers (LNE-Cnam), Paris, FRANCE
Risegari, Lara; Laboratoire National et d'Essais, National des Arts et Métiers (LNE-Cnam), Paris, FRANCE
Widiatmo, Januarius; National Metrology Institute of Japan, Advanced Industrial Science and Technology (NMIJ/ AIST), Tsukuba, JAPAN
Nakano, Tohru; National Metrology Institute of Japan, Advanced Industrial Science and Technology (NMIJ/ AIST), Tsukuba, JAPAN
Saito, Ikuhiko; National Metrology Institute of Japan, Advanced Industrial Science and Technology (NMIJ/ AIST), Tsukuba, JAPAN
Quelhas, Klaus Natorf; Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (INMETRO), Rio de Janeiro, BRAZIL
Giorgio, Patricia; Instituto Nacional de Tecnologia Industrial (INTI), ARGENTINA
Sun, Jianping; National Institute of Metrology (NIM), Beijing, Republic of CHINA
Zhang, Jintao; National Institute of Metrology (NIM), Beijing, Republic of CHINA
Pearce, Jonathan; National Physical Laboratory (NPL), Teddington, UK
Gray, Jayne; National Physical Laboratory (NPL), Teddington, UK
Quelle/Jahr Metrologia: 60 (2023), 1A, 1 - 152
Artikelnummer 03001
Availability [online only]
ISSN 0026-1394 (print) ; 1681-7575 (online)
DOI
Verlag Bristol: IOP Publishing
Zusammenfassung This is a report to the Consultative Committee for Thermometry (CCT) on the key comparison 9 of Standard Platinum Resistance Thermometer (SPRT) calibration on the International Temperature Scale of 1990 (ITS-90) from 83.8058 K (the Ar triple point) to 692.677 K (the Zn freezing point). The comparison followed a collapsed star protocol, with each of the fourteen participating laboratories shipping two standard platinum resistance thermometers (SPRTs) as transfer standards to the pilot laboratory (National Institute of Standards and Technology, NIST) for a direct comparison of SPRT calibration at the National Metrology Institute (NMI) of origin to calibration at NIST. Measurements were taken at the participating laboratories before and after measurement at NIST to assess the effect of transportation on the transfer standards. The pooled results from all laboratories were combined to calculate a key comparison reference value (KCRV). This report includes the calculation of, and comparisons to, the KCRV as well as bilateral comparisons between labs. In addition, there is space devoted to analysis of the shifts in SPRT values following travel.

Zitierung

Herman, T., Chojnacky, M., Hill, K., Rudtsch, S., Yang, I., Steur, P. P., Dematteis, R., Lopardo, G., Sparasci, F., Martin, C., Risegari, L., Widiatmo, J., Nakano, T., Saito, I., Quelhas, K. N., Giorgio, P., Sun, J., Zhang, J., Pearce, J., & Gray, J. (2023). Key Comparison CCT-K9 : ITS-90 SPRT calibration from the Ar TP to the Zn FP. Metrologia, 60(1A), 1–152. https://doi.org/10.1088/0026-1394/60/1A/03001

Exportieren