Zugriffsnummer 52964
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel An improved 10 mA /10 V standard for the CERN DC-current calibrator
Autor(in); Institution
Pickering, John; Metron Designs, Norwich, UK
Beev, Nikolai; European Organization for Nuclear Research (CERN), Geneva, SWITZERLAND; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Bratislava, SLOVAKIA
Cerqueira Bastos, Miguel; European Organization for Nuclear Research (CERN), Geneva, SWITZERLAND
Valuch, Daniel; European Organization for Nuclear Research (CERN), Geneva, SWITZERLAND; Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, Bratislava, SLOVAKIA
Hudson, Greg; European Organization for Nuclear Research (CERN), Geneva, SWITZERLAND
Palafox Gamir, Luis; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Behr, Ralf; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Quelle/Jahr 2024 Conference on Precision Electromagnetic Measurements (CPEM):(2024), 2 S.
ISSN 2160-0171 (online) ; 0589-1485 (PoD)
ISBN 979-8-3503-6104-9 (online) ; 979-8-3503-6105-6 (PoD)
DOI
Verlag Piscataway, NJ: IEEE
Konferenzangaben Conference on Precision Electromagnetic Measurements (CPEM 2024), Denver, Colo., 8-12, July, 2024, USA
Freie Schlagworte measurement ; calibration ; measurement standards ; precision measurements ; Large Hadron Collider
Zusammenfassung An improved 10 V / 10 mA standard is presented, which is part of the test infrastructure for direct current current transformers (DCCTs) for the High Luminosity Large Hadron Collider (HL-LHC) project at CERN. It serves primarily as a reference source for the 10 A CERN current calibrator (CDC), but also as a 10 V source with extremely low noise at sub-Hz frequencies. Improvements were made in the internal voltage reference and voltage-to-current conversion circuits. Measurements against the PTB programmable Josephson voltage standard (PJVS) show 1/f noise-limited Allan deviation at 10 V on the order of 5 · 10-8 V for measurement times of seconds to hours.
Themenbereich der Metrologie Elektrizität und Magnetismus

Zitierung

Pickering, J., Beev, N., Cerqueira Bastos, M., Valuch, D., Hudson, G., Palafox Gamir, L., & Behr, R. (2024). An improved 10 mA /10 V standard for the CERN DC-current calibrator. Conference on Precision Electromagnetic Measurements (CPEM 2024), Denver, Colo., 8-12, July, 2024, USA. https://doi.org/10.1109/CPEM61406.2024.10646156

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag