Zugriffsnummer 52858
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Reproducibility of tailored and universal non-selective excitation pulses at 7T for human cardiac body imaging: A 3-year and an inter-day study
Autor(in); Institution
Alarcón, Manuel Fernando Sánchez; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Dietrich, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Bassenge, Jean Pierre; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin; Charité – Universitätsmedizin Berlin, Berlin, GERMANY
Schulz-Menger, Jeanette; Charité - Universitätsmedizin Berlin, Berlin, GERMANY
Schmitter, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin; edical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, GERMANY; Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, UNITED STATES
Aigner, Christoph Stefan; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Quelle/Jahr Proceedings of the International Society for Magnetic Resonance in Medicine:(2024), 1 - 2
Artikelnummer 0521
ISSN 1065-9889
DOI
Konferenzangaben ISMRM & ISMRT Annual Meeting & Exhibition, Singapore, 04-09, May, 2024, Singapore
Freie Schlagworte RF Pulse Design & Fields ; High-Field MRI ; Reproducibility ; Universal pulse ; 7T ; pTx
Zusammenfassung Ultra-high field (UHF) body MRI faces challenges due to inherent spatial variations in flip angle (FA) patterns. Subject-specific parallel transmission (pTx) methods, relying on personalized B+1 -maps, ensure high FA uniformity in the cardiac region. In contrast, using cardiac universal pulses (UPs) offers time-saving benefits and robustness for various RF coil placements, while also achieving FA uniformity in surrounding tissues, including the aorta. This study assesses the reproducibility and variability of three excitation methods in six subjects: default excitation, 4kT-points subject-tailored pTx (TP), and calibration-free UP. In addition to a previous study , three different MRI operators conducted re-scans at one- and two-year intervals, including inter-day scans by two different operators.

Zitierung

Alarcón, M. F. S., Dietrich, S., Bassenge, J. P., Schulz-Menger, J., Schmitter, S., & Aigner, C. S. (2024). Reproducibility of tailored and universal non-selective excitation pulses at 7T for human cardiac body imaging: A 3-year and an inter-day study. ISMRM & ISMRT Annual Meeting & Exhibition, Singapore, 04-09, May, 2024, Singapore. https://doi.org/10.58530/2024/0521

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag