Titel Impact of RF imperfections on MRF--based and reference B mapping methods with a commercial 1Tx/32Rx head coil
Autor(in); Institution
Lutz, Max; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Silemek, Berk; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Seifert, Frank; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Aigner, Christoph Stefan; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Orzada, Stephan; Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, GERMANY
DelaBarre, Lance; Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, UNITED STATES
Schäffter, Tobias; 8, Medizinphysik und metrologische Informationstechnik, PTB-Berlin; Einstein Center Digital Future, Berlin, Germany, Department of Biomedical Engineering, Technical University of Berlin, Berlin, GERMANY
Schmitter, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin; Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, GERMANY; Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, UNITED STATES
Quelle/Jahr Proceedings of the International Society for Magnetic Resonance in Medicine:(2024), 1 - 2
Artikelnummer 0473
ISSN 1065-9889 (online)
DOI
Verlag ISMRM
Konferenzangaben ISMRM & ISMRT Annual Meeting & Exhibition, Singapore, 04-09, May, 2024, Singapore
Freie Schlagworte System Imperfections ; System Imperfections: Measurement & Correction
Zusammenfassung Accuracy and precision of MRI experiments strongly rely on hardware fidelity. While gradient imperfections receive considerable attention, RF imperfections are often disregarded. RF correction methods have been proposed for complex pTx or multiband applications, however, imperfections within the RF-chain (amplifier and coil) would also a!ect absolute quantification techniques with simpler RF-waveforms, in particular precise B+1 -mapping methods that are necessary for coil validation or for quantitative corrections. Here, we report deviations from the expected RF signal that we observed by pick-up coil measurements in MRF based B+1 - mapping scans in comparison to a reference B+1 -mapping approach using a commercial 1Tx/32Rx head coil. Furthermore, we investigate the temporal stability of the MRF-pattern and its impact on the resulting values.

Zitierung

Lutz, M., Silemek, B., Seifert, F., Aigner, C. S., Orzada, S., DelaBarre, L., Schäffter, T., & Schmitter, S. (2024). Impact of RF imperfections on MRF--based and reference B mapping methods with a commercial 1Tx/32Rx head coil. ISMRM & ISMRT Annual Meeting & Exhibition, Singapore, 04-09, May, 2024, Singapore. https://doi.org/10.58530/2024/0473