Zugriffsnummer 52302
Dokumenttyp Zeitschriftenartikel Open Access Hybrid
Peer Review mit Peer Review
Sprache Englisch
Titel Accelerated B1+ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7 T
Autor(in); Institution
Egger, Nico; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, GERMANY
Nagelstraßer, Sophia; Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, GERMANY
Wildenberg, Saskia; Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, GERMANY
Bitz, Andreas; Electrical Engineering and Information Technology, University of Applied Sciences - FH Aachen, Aachen, GERMANY
Ruck, Laurent; Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, GERMANY
Herrler, Jürgen; Siemens Healthcare, Erlangen, Bavaria, GERMANY
Meixner, Christian Rainer; Siemens Healthcare, Erlangen, Bavaria, GERMANY
Kimmlingen, Ralph; Siemens Healthcare, Erlangen, Bavaria, GERMANY
Lanz, Titus; Rapid Biomedical, Rimpar, GERMANY
Schmitter, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Uder, Michael; Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, GERMANY
Nagel, Armin Michael; Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, GERMANY
Quelle/Jahr Magnetic Resonance in Medicine: 92 (2024), 5, 1933 - 1951
ISSN 0740-3194 (print) ; 1522-2594 (online)
DOI
Verlag New York, NY: Wiley
Freie Schlagworte 7 Tesla ; B+1 mapping ; heart ; parallel transmission ; prostate ; ultra high-field
Zusammenfassung Purpose To investigate the impact of reduced k-space sampling on B+1 mapping and the resulting impact on phase shimming and dynamic/universal parallel transmit (pTx) RF pulse design. Methods Channel-wise 3D  B+1 maps were measured at 7 T in 35 and 23 healthy subjects for the heart and prostate region, respectively. With these B+1 maps, universal phase shims optimizing homogeneity and B+1 efficiency were designed for heart and prostate imaging. In addition, universal 4kT-point pulses were designed for the heart. Subsequently, individual phase shims and individual 4kT-pulses were designed based on B+1 maps with different acceleration factors and tested on the original maps. The performance of the pulses was compared by evaluating their coefficients of variation (CoV),  B+1 efficiencies and specific energy doses (SED). Furthermore, validation measurements were carried out for one heart and one prostate subject. Results For both organs, the universal phase shims showed significantly higher B+1 efficiencies and lower CoVs compared to the vendor provided default shim, but could still be improved with individual phase shims based on accelerated maps (acquisition time = 30 s). In the heart, the universal 4kT-pulse achieved significantly lower CoVs than tailored phase shims. Tailored 4kT-pulses based on accelerated  B+1 maps resulted in even further reduced CoVs or a 2.5-fold reduction in SED at the same CoVs as the universal 4kT-pulse. Conclusion Accelerated B+1maps can be used for the design of tailored pTx pulses for prostate and cardiac imaging at 7 T, which further improve homogeneity,  B+1 efficiency, or SED compared to universal pulses.
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Förderinformationen (1) Förderername: Open Access funding enabled and organized by Projekt DEAL

Zitierung

Egger, N., Nagelstraßer, S., Wildenberg, S., Bitz, A., Ruck, L., Herrler, J., Meixner, C. R., Kimmlingen, R., Lanz, T., Schmitter, S., Uder, M., & Nagel, A. M. (2024). Accelerated B1+ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7 T. Magnetic Resonance in Medicine, 92(5), 1933–1951. https://doi.org/10.1002/mrm.30185

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag