Zugriffsnummer 52201
Dokumenttyp Zeitschriftenartikel Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Two new 222Rn emanation sources - a comparison study
Autor(in); Institution
Ballé, Tanita; 6.1, Radioaktivität, PTB-Braunschweig
Röttger, Stefan; 6.1, Radioaktivität, PTB-Braunschweig
Mertes, Florian; PTB-Braunschweig, formerly
Honig, Anja; 6.1, Radioaktivität, PTB-Braunschweig
Kovar, Petr; Czech Metrology Institute (CMI), Regional Branch Prague, Prague, CZECH REPUBLIC
Ot.aacute.hal, Petr P. S.; National Institute for Nuclear, Biological and Chemical Protection, Nuclear Protection Department, Milín, CZECH REPUBLIC
Röttger, Annette; Präsidium, MP, PTB-Braunschweig
Quelle/Jahr Atmospheric Measurement Techniques: 17 (2024), 2055 - 2065
ISSN 1867-1381 (print) ; 1867-8548 (online)
DOI
Verlag Katlenburg-Lindau: Copernicus
Zusammenfassung More than 50 % of naturally occurring radiation exposure to the general public is due to the noble gas radon (222Rn) and its progenies, causing considerable health risks. Therefore, the European Union has implemented Council Directive 2013/59/EURATOM to measure 222Rn activity concentrations and to identify radon priority areas (RPAs) to specify areas where countermeasures are most needed. Although 222Rn measurements are far spread across Europe, traceability to the International System of Units (SI) is still lacking for radon activity concentrations below 300 Bq m-3. Consequently, measurement results cannot be reliably compared with each other. The European Metrology Research Programme for Innovation and Research (EMPIR) 19ENV01 traceRadon project aimed to address this issue and has developed two new 222Rn emanation sources, intended to be used as calibration standards for reference instruments. The goal of this paper is to investigate and compare the two sources to ensure their quality by comparing the calibration factors estimated from both sources for the same reference instrument. This was done for three reference instruments in total at two experimental sites. Differences in calibration factors for one reference instrument of up to 0.07 were derived. Despite the small differences between the calibration factors, all uncertainties are well within the intended target uncertainty of 10 % for k = 1.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Ionisierende Strahlung
Forschungsprojekt 19ENV01: traceRadon: Radon metrology for use in climate change observation and radiation protection at the environmental level
Förderinformationen (1) Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989
Förderer ID Typ: ISNI
Förderprogramm: EMPIR 2019 Environment
Titel der Förderung: 19ENV01: traceRadon: Radon metrology for use in climate change observation and radiation protection at the environmental level
Förderungsnummer: 19ENV01
URI der Förderung: http://traceradon-empir.eu/

Zitierung

Ballé, T., Röttger, S., Mertes, F., Honig, A., Kovar, P., Ot.aacute.hal, P. P. S., & Röttger, A. (2024). Two new ²²²Rn emanation sources - a comparison study. Atmospheric Measurement Techniques, 17, 2055–2065. https://doi.org/10.5194/amt-17-2055-2024

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag