Zugriffsnummer 52015
Dokumenttyp Konferenzartikel in Zeitschrift Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Analysis of the interpolation parameters to estimate the errors at specific force values in continuous calibration
Autor(in); Institution
Sander, Jonas; 1.2, Festkörpermechanik, PTB-Braunschweig
Oliveira, Rafael S.; National Institute of Metrology Standardization and Industrial Quality (INMETRO), Rio de Janeiro, BRAZIL
Wellington, Fernandes G.; Instituto Nacional de Tecnologia, Rio de Janeiro, BRAZIL
Tegtmeier, Falk; 1.2, Festkörpermechanik, PTB-Braunschweig
Knott, Andy; National Physical Laboratory (NPL), Teddington, UK
Quelle/Jahr Proceedings of the XXIV IMEKO World Congress. Measurement: Sensors: 38 (2025), Suppl., e1 - e7
Artikelnummer 101376
Availability [online only]
ISSN 2665-9174 (online)
DOI
Verlag Amsterdam: Elsevier
Konferenzangaben XXIV IMEKO World Congress 2024 "Think Metrology", Hamburg, 26-29, August, 2024, Germany
Freie Schlagworte Continuous calibration ; linear regression ; interpolation ; ISO 7500-1 ; ISO 376
Zusammenfassung The Euramet project 18SIB08 "ComTraForce" developed research to improve the continuous calibration procedures intended to be added to the under review standards that traditionally deals with static force calibration, such as ISO 376 and ISO 7500-1. Among these procedures is the description of a method for the adequate synchronous correlation between the force signals of the reference and the device under test to estimate the indication error for a specific force target value. This method describes the necessity to carry out a double interpolation sequence, using linear least squares adjustments. This paper presents a study on the impact of selecting different ranges of points on the estimation of the interpolation coefficients and the consequent impact on the calculation of the indication errors. The statistical parameters of these curves are also discussed. Experimental data was obtained from measurement series with different force rates carried out in an assembly with a testing machine and a reference sensor.
Kostenfreier Zugang Open Access Gold
Themenbereich der Metrologie Masse und abgeleitete Größen
Geschäftsfelder Metrologie für die Wirtschaft
Förderinformationen (1) Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989
Förderer ID Typ: ISNI
Förderprogramm: EMPIR 2018 SI Broader Scope
Titel der Förderung: 18SIB08: ComTraForce: Comprehensive traceability for force metrology services
Förderungsnummer: 18SIB08

Zitierung

Sander, J., Oliveira, R. S., Wellington, F. G., Tegtmeier, F., & Knott, A. (2025). Analysis of the interpolation parameters to estimate the errors at specific force values in continuous calibration. Measurement: Sensors, 38(Suppl.), e1–e7. https://doi.org/10.1016/j.measen.2024.101376

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag