Titel Active personal eye lens dosimetry with the hybrid pixelated dosepix detector
Autor(in); Institution
Beißer, Florian; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, GERMANY
Haag, Dennis; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, GERMANY
Ballabriga, Rafael; CERN, Geneva, SWITZERLAND
Behrens, Rolf; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Campbell, Michael; CERN, Geneva, SWITZERLAND
Fuhg, Christian; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Hufschmidt, Patrick; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, GERMANY
Hupe, Oliver; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Kupillas, Carolin; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, GERMANY
Llopart, Xavier; CERN, Geneva, SWITZERLAND
Roth, Jürgen; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Schmidt, Sebastian; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, GERMANY
Schneider, Markus; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, GERMANY
Tlustos, Lukas; CERN, Geneva, SWITZERLAND; Czech Technical University in Prague, Institute of Experimental and Applied Physics, Prague, CZECH REPUBLIC
Wong, Winnie; CERN, Geneva, SWITZERLAND; Mercury Systems, Geneva, SWITZERLAND
Zutz, Hayo; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Michel, Thilo; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, GERMANY
Quelle/Jahr IEEE Transactions on Radiation and Plasma Medical Sciences: 7 (2023), 8, 879 - 887
ISSN 2469-7311 (print) ; 2469-7303 (online)
DOI
Verlag New York, NY: IEEE
Freie Schlagworte Active personal dosemeter ; eye lens dosimetry ; Dosepix ; dosimetry for interventional procedures ; dosimetry for radiation-based medical applications ; pulsed X-ray fields ; radiation detectors for medical applications: semiconductors
Zusammenfassung Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at 3 mm depth of soft tissue, Hp(3) , was measured in the center front of a water-filled cylinder phantom with a height and diameter of 20 cm. The energy dependence of the normalized response is investigated for mean photon energies between 12.4 and 248keV for continuous reference radiation fields (N-series) according to ISO 4037. The response normalized to N- 60(E=47.9keV) at 0° angle of irradiation stays within the approval limits of IEC 61526 for angles of incidence between −75° and +75° . Performance in pulsed photon fields was tested for varying dose rates from 0.1(Sv/h) up to 1000(Sv/h) and pulse durations from 1ms up to 10s . The dose measurement works well within the approval limits (acc. to IEC 61526) up to 1(Sv/h) . No significant influence of the pulse duration on the measured dose is found. Reproducibility measurements yield a coefficient of variation which does not exceed 1% for two tested eye lens dosemeter prototypes.
Themenbereich der Metrologie Ionisierende Strahlung
Innovationscluster Gesundheit
Geschäftsfelder Grundlagen der Metrologie

Zitierung

Beißer, F., Haag, D., Ballabriga, R., Behrens, R., Campbell, M., Fuhg, C., Hufschmidt, P., Hupe, O., Kupillas, C., Llopart, X., Roth, J., Schmidt, S., Schneider, M., Tlustos, L., Wong, W., Zutz, H., & Michel, T. (2023). Active personal eye lens dosimetry with the hybrid pixelated dosepix detector. IEEE Transactions on Radiation and Plasma Medical Sciences, 7(8), 879–887. https://doi.org/10.1109/TRPMS.2023.3301503