Titel A simulation-based phantom model for generating synthetic mitral valve image data–application to MRI acquisition planning
Autor(in); Institution
Manini, C.; Institute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Nemchyna, O.; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Akansel, S.; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Walczak, L.; Institute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Tautz, L.; Fraunhofer MEVIS, Berlin, GERMANY
Kolbitsch, Christoph; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Falk, V.; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Sündermann, S.; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Kühne, T.; Institute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Schulz-Menger, J.; Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität Zu Berlin, Berlin, GERMANY
Hennemuth, A.; Institute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, GERMANY
Quelle/Jahr International Journal of Computer Assisted Radiology and Surgery: 19 (2024), 553 - 569
ISSN 1861-6410 (print) ; 1861-6429 (online)
DOI
Verlag Berlin: Springer
Zusammenfassung Purpose Numerical phantom methods are widely used in the development of medical imaging methods. They enable quantitative evaluation and direct comparison with controlled and known ground truth information. Cardiac magnetic resonance has the potential for a comprehensive evaluation of the mitral valve (MV). The goal of this work is the development of a numerical simulation framework that supports the investigation of MRI imaging strategies for the mitral valve. Methods We present a pipeline for synthetic image generation based on the combination of individual anatomical 3D models with a position-based dynamics simulation of the mitral valve closure. The corresponding images are generated using modality-specific intensity models and spatiotemporal sampling concepts. We test the applicability in the context of MRI imaging strategies for the assessment of the mitral valve. Synthetic images are generated with different strategies regarding image orientation (SAX and rLAX) and spatial sampling density. Results The suitability of the imaging strategy is evaluated by comparing MV segmentations against ground truth annotations. The generated synthetic images were compared to ones acquired with similar parameters, and the result is promising. The quantitative analysis of annotation results suggests that the rLAX sampling strategy is preferable for MV assessment, reaching accuracy values that are comparable to or even outperform literature values. Conclusion The proposed approach provides a valuable tool for the evaluation and optimization of cardiac valve image acquisition. Its application to the use case identifies the radial image sampling strategy as the most suitable for MV assessment through MRI..
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Metrologie in der Medizin

Zitierung

Manini, C., Nemchyna, O., Akansel, S., Walczak, L., Tautz, L., Kolbitsch, C., Falk, V., Sündermann, S., Kühne, T., Schulz-Menger, J., & Hennemuth, A. (2024). A simulation-based phantom model for generating synthetic mitral valve image data–application to MRI acquisition planning. International Journal of Computer Assisted Radiology and Surgery, 19, 553–569. https://doi.org/10.1007/s11548-023-03012-y