Zugriffsnummer 50700
Dokumenttyp Repository E-Print Open Access Gold
Peer Review unbekannt
Sprache Englisch
Titel Report describing the calibration of the 5 MN m torque transfer standard partially up to 1.1 MN m with an uncertainty < 0.1 % and in the full range up to 5 MN m with an uncertainty < 0.5 % with synchronised measurements of rotational speed up to 20 rpm on the low-speed shaft respectively torque measurements up to 100 kN m with synchronised measurements of rotational speed up to 1600 rpm on the high-speed shaft
Autor(in); Institution
Weidinger, Paula; 1.2, Festkörpermechanik, PTB-Braunschweig
Song, Zihang; 1.2, Festkörpermechanik, PTB-Braunschweig
Soares de Oliveira, Rafael; INMETRO - Instituto Nacional de Metrologia Qualidade e Tecnologia, Rio de Janeiro, BRAZIL
Vavrecka, Lukas; Czech Metrology Institute (CMI), Brno, CZECH REPUBLIC
Fidelus, Janusz; GUM Central Office of Measures/Glówny Urzad Miar (GUM), Warszawa, POLAND
Kananen, Timo; VTT VTT Technical Research Centre of Finland, Espoo, FINLAND
Heller, Marcel; FhG IWES, Bremerhaven, GERMANY
Zhang, Hongkun; FhG IWES, Bremerhaven, GERMANY
Quelle/Jahr (2023), ii, 47 S.
Availability [online only]
DOI
URL
Verlag Zenodo
Zusammenfassung This report has been produced within the EMPIR project entitled Traceable Mechanical and Electrical Power Measurement for Efficiency Determination of Wind Turbines or 19ENG08 WindEFCY. More information about this collaborative research project can be found on the project’s website https://www.ptb.de/empir2020/windefcy/home/. This report describes the calibration of the 5 MN m torque transfer standard partially up to 1.1 MN m including an extrapolation of the calibration results up to 5 MN m as well as the use of the transducer under rotation up to 22.5 rpm. Moreover, a 125 kN m torque transducer was calibrated statically for usage under rotation up to 1600 rpm. Other influences on statically calibrated transducers when used in test benches, such as different data acquisition and filter settings, rotational speed and non-step application of loads, were investigated.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Masse und abgeleitete Größen
Forschungsprojekt 19ENG08: WindEFCY: Traceable mechanical and electrical power measurement for efficiency determination of wind turbines
Förderinformationen (1) Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989
Förderer ID Typ: ISNI
Förderprogramm: EMPIR 2019 Energy
Titel der Förderung: 19ENG08: WindEFCY: Traceable mechanical and electrical power measurement for efficiency determination of wind turbines
Förderungsnummer: 19ENG08

Zitierung

Weidinger, P., Song, Z., Soares de Oliveira, R., Vavrecka, L., Fidelus, J., Kananen, T., Heller, M., & Zhang, H. (2023). Report describing the calibration of the 5 MN m torque transfer standard partially up to 1.1 MN m with an uncertainty < 0.1 % and in the full range up to 5 MN m with an uncertainty < 0.5 % with synchronised measurements of rotational speed up to 20 rpm on the low-speed shaft respectively torque measurements up to 100 kN m with synchronised measurements of rotational speed up to 1600 rpm on the high-speed shaft. https://doi.org/10.5281/zenodo.8112428

Exportieren