Zugriffsnummer 50357
Dokumenttyp Konferenzartikel in Zeitschrift Freier Zugang
Peer Review mit Peer Review
Sprache Englisch
Titel EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18)
Autor(in); Institution
Zivanovic, Milos; Vinca Institute of Nuclear Sciences, Belgrade, SERBIA
Hupe, Oliver; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Zutz, Hayo; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Sabeta, Amra; Institute of Metrology of Bosnia and Herzegovina, Sarajevo, BOSNIA AND HERZEGOVINA
Sandtner, Stanislav; Slovak Institute of Metrology, Department of Ionizing Radiation, Bratislava, SLOVAKIA
Krzanovic, Nikola; Vinca Institute of Nuclear Sciences, Belgrade, SERBIA
Quelle/Jahr Metrologia: 60 (2023), 1A, Tech. Suppl., 135 S.
Artikelnummer 06017
Availability [online only]
ISSN 0026-1394 (print) ; 1681-7575 (online)
DOI
Verlag Bristol: IOP Publishing
Konferenzangaben Conference of Radiation Protection Association of Serbia and Montenegro, Divcibare, 2-4, October, 2019, Hungary
Zusammenfassung A supplementary comparison in terms of the ambient dose equivalent/rate was organized within EURAMET as a part of the DOSEtrace project, between 13 national metrology institutes and designated institutes. Calibration coefficients were compared for a secondary standard ionisation chamber for 3 X-ray and 2 γ-ray radiation qualities used in the field of radiation protection. Radiation qualities were established according to ISO 4037-1. Measurements were performed between 2019 and 2021. For the purpose of this comparison, it was considered that the reported uncertainty was confirmed if the relative deviation from the comparison reference value was smaller than or equal to the associated uncertainty. All the reported results by all the partners satisfied this criterium. Three participants were not able to perform calibrations in all mandatory radiation qualities, due to technical problems. The results are published in the Key Comparison Data Base (KCDB) of the BIPM as supplementary comparison EURAMET.RI(I)-S18. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Kostenfreier Zugang Freier Zugang
Themenbereich der Metrologie Ionisierende Strahlung

Zitierung

Zivanovic, M., Hupe, O., Zutz, H., Sabeta, A., Sandtner, S., & Krzanovic, N. (2023). EURAMET DOSEtrace supplementary comparison in terms of the ambient dose equivalent/rate for photon radiation (EURAMET.RI(I)-S18). Metrologia, 60(1A, Tech. Suppl.), 135 S. https://doi.org/10.1088/0026-1394/60/1A/06017

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag