Zugriffsnummer 49531
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel A fundamental step-up method for calibrating active compensated current comparators of highest accuracy
Autor(in); Institution
Dubowik, Alexander; 2.3, Elektrische Energiemesstechnik, PTB-Braunschweig
Mohns, Enrico; 2.3, Elektrische Energiemesstechnik, PTB-Braunschweig
Quelle/Jahr 2022 Conference on Precision Electromagnetic Measurements (CPEM), Full Digest: (2022):(2022), 1 - 2
ISBN 978-1-6654-7270-8/22 (PDF)
Konferenzangaben Conference on Precision Electromagnetic Measurements (CPEM) 2022, Wellington, 12-16, December, 2022, New Zealand
Freie Schlagworte current transformer ; alternating current measurements ; calibration ; current comparator ; power frequency ; precision current measurements ; uncertainty
Zusammenfassung This paper presents a step-up method for calibrating a set of error compensated current comparators of PTBs instrument transformer laboratory for the use as current transformer reference standards. The method is based on some assumptions and previous knowledge about the error characteristics of first CC of the set. Extensive measurements between the CCs confirm the assumptions made and show for first CC, that its ratio and phase errors are in the 10-7 range, while its uncertainties are in the same order.
Themenbereich der Metrologie Elektrizität und Magnetismus

Zitierung

Dubowik, A. & Mohns, E. (2022). A fundamental step-up method for calibrating active compensated current comparators of highest accuracy. Conference on Precision Electromagnetic Measurements (CPEM) 2022, Wellington, 12-16, December, 2022, New Zealand.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag