Zugriffsnummer 49494
Dokumenttyp Zeitschriftenartikel Open Access Hybrid
Peer Review mit Peer Review
Sprache Englisch
Titel Assessment of 2D-based tests for the qualification of simulation software for dXCT
Autor(in); Institution
Borges de Oliveira, Fabrício; 5.3, Koordinatenmesstechnik, PTB-Braunschweig
Reuter, Tamara; Friedrich-Alexander-Universität Erlangen-Nürnberg, Chair of Manufacturing Metrology (FMT), GERMANY
Plotzki, David; BAM, Berlin, GERMANY
Wohlgemuth, Florian; HEITEC PTS GmbH, Kuchen, GERMANY
Bartscher, Markus; 5.3, Koordinatenmesstechnik, PTB-Braunschweig
Bellon, Carsten; BAM, Berlin, GERMANY
Kasperl, Stefan; Frauhofer Development Center for X-ray Technology (EZRT), Fürth, GERMANY
Quelle/Jahr Measurement Science and Technology: 34 (2023), 6, 1 - 12
Artikelnummer 064005
ISSN 0957-0233 (print) ; 1361-6501 (online)
DOI
Verlag Bristol: IOP Publishing
Freie Schlagworte X-ray computed tomography ; dXCT ; simulation
Zusammenfassung The interest in using computer simulations of dimensional x-ray computed tomography (dXCT) for various metrological purposes - such as measurement planning, performance prediction, performance optimisation and, finally, measurement uncertainty estimation - is increasing along with the ever-growing demand for more reliable measurements with dXCT. However, before a piece of simulation software can be used for tasks related to coordinate metrology, it has to be ensured that it is able to simulate physical laws, characteristic effects and basic CT system functionalities correctly and with sufficient accuracy. In short, the software must be qualified for dimensional metrology tasks. As one part of such a qualification process, a method is presented here for determining conformity intervals of 2D tests (projection-based tests) based on 3D tests (testing based on dimensional evaluations in a reconstructed volume) for the assessment of dXCT simulation software. The method consists of varying relevant parameter values in order to verify their influence on 3D measurement results. The results of the 3D tests with varied parameter values are then transferred to the quantities tested in the 2D tests and used as the basis for determining conformity intervals. Two approaches are applied for determining whether or not a variation of a parameter value is significant: (a) statistical and (b) heuristic. Two examples are presented, each based on simulated images, which show the application of the two different approaches for determining conformity intervals for the results of the 2D tests.
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Länge, dimensionelle Metrologie
Innovationscluster Digitalisierung
Geschäftsfelder Metrologie für die Wirtschaft
Forschungsprojekt WIPANO CTSimU
Förderinformationen (1) Förderername: Bundesministerium für Wirtschaft und Klimaschutz (BMWK)
Förderer ID: 0000 0001 0945 2036
Förderer ID Typ: ISNI
Titel der Förderung: WIPANO CTSimU
Förderungsnummer: 03TNH026D

Zitierung

Borges de Oliveira, F., Reuter, T., Plotzki, D., Wohlgemuth, F., Bartscher, M., Bellon, C., & Kasperl, S. (2023). Assessment of 2D-based tests for the qualification of simulation software for dXCT. Measurement Science and Technology, 34(6), 1–12. https://doi.org/10.1088/1361-6501/acc1f9

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag