Zugriffsnummer 48980
Dokumenttyp Konferenzartikel Open Access Gold
Peer Review unbekannt
Sprache Englisch
Titel Analysis of flanged joints for flameproof enclosed devices of gas group IIC according to the standard IEC 60079-1
Autor(in); Institution
Padrón Herrera, Victor Hugo; 3.5, Explosionsschutz in der Energietechnik, PTB-Braunschweig
Dymke, Jessica; 3.5, Explosionsschutz in der Energietechnik, PTB-Braunschweig
Springer, Niels; 3.5, Explosionsschutz in der Energietechnik, PTB-Braunschweig
Markus, Detlev; 3.5, Explosionsschutz in der Energietechnik, PTB-Braunschweig
Quelle/Jahr Proceedings of the 14th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions:(2022), 348 - 359
Availability [online only]
DOI
Verlag PTB Open Access Repository
Konferenzangaben 14th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions ; ISHPMIE, Braunschweig, 11-15, July, 2022, Germany
Freie Schlagworte small volumes ; flameproof enclosure ; flanged joint ; test for non-transmission of an internal ignition ; reference pressure test
Zusammenfassung Due to the miniaturization of electronic components and circuits, as a result of the everadvancing innovative optimization process, manufacturers of flameproof enclosures have the necessity to adapt their flameproof enclosures for smaller internal free volumes. The standard IEC 60079-1 for the type of protection Flameproof Enclosure "d" defines several internal free volume groups that go along with constructive requirements for the different types of joints. Nevertheless, the use of flanged joints for group IIC devices is very limited. Under the occurrence of acetylene containing atmospheres, they are only permitted if the internal free volume is ≤ 500 cm³ However, the requirements are not suitable for enclosures with small internal free volumes. This paper shows, after a first testing process, the minimum requirements for flameproof flanged joints of a small-internal free volume enclosure with a specific internal geometry. Here tests for non-transmission of an internal ignition and reference pressure tests with an enclosure with approximately 0.09 cm³ internal free volume are presented. In the end, a deeper understanding of the flame transmission in flanged joints of Group IIC in flameproof enclosed equipment will be achieved.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY-ND 4.0 ; Creative Commons Attribution NoDerivatives 4.0 License
Themenbereich der Metrologie Physikalische Sicherheitstechnik, Explosionsschutz

Zitierung

Padrón Herrera, V. H., Dymke, J., Springer, N., & Markus, D. (2022). Analysis of flanged joints for flameproof enclosed devices of gas group IIC according to the standard IEC 60079-1. 14th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions ; ISHPMIE, Braunschweig, 11-15, July, 2022, Germany. https://doi.org/10.7795/810.20221124