| Zugriffsnummer | 48970 |
| Dokumenttyp | Bericht |
| Peer Review | unbekannt |
| Sprache | Englisch |
| Titel | Comparison on material parameter measurements in the THz spectral range with optical, resonant and VNA based setups |
| Autor(in); Institution |
Allal, Djamel; Bureau National de Metrologie (LNE), Paris, FRANCE
Gäumann, Gregory; METAS, Bern-Wabern, SWITZERLAND
Gregory, Andrew; National Physical Laboratory, Materials Processing and Performance Group, Teddington, UK
Hudlicka, Martin; Czech Metrology Institute (CMI), Brno, CZECH REPUBLIC
Kazemipour, Alireza; METAS, Bern-Wabern, SWITZERLAND
Premysl, Marsik; Universität Freiburg, Freiburg, GERMANY
Naftaly, Mira; National Physical Laboratory, Materials Processing and Performance Group, Teddington, UK
Sakarya, Handan; TÜBITAK UME National Metrology Institute, Gebze, Kocaeli, TURKEY
Shang, Xiaobang; National Physical Laboratory, Materials Processing and Performance Group, Teddington, UK
Ulm, David; 2.2, Hochfrequenz und Felder, PTB-Braunschweig
Wojciechowski, Marcin; Central Office of Measures (GUM), Warsaw, POLAND
Zagrajek, Przemyslaw; Institute of Optoelectronics, Military University of Technology, Warsaw, POLAND
|
| Quelle/Jahr | (2022), iii, 100 S. |
| URL | |
| Berichtsnummer | 1514 |
| Verlag | Braunschweig: EURAMET |
| Zusammenfassung | This pilot study was part of the EMPIR (18SIB09) TEMMT project. Therein, different methods for material parameter measurements in the THz spectral range have been compared. The different measurement setups include optical (TDS or FDS) and resonant or VNA-based systems, all of which have unique properties like e.g. spectral coverage and system dynamics. The comparison covered a frequency range from approximately 100 GHz up to several THz. Part of the study was also to evaluate frequency limits of the different setups. A set of reference materials has been measured by as many setups as possible. In addition, the measurements have been analysed with different material parameter extraction methods to study and compare different algorithms. In a final report, results are presented and compared with the associated uncertainties for the real and imaginary parts of permittivity. This shows the advantages and disadvantages of each method and setup in terms of sensitivity, stability and spectral coverage. |
| Themenbereich der Metrologie | Elektrizität und Magnetismus |
| Forschungsprojekt | 18SIB09: TEMMT: Traceability for electrical measurements at millimetre-wave and terahertz frequencies for communications and electronics technologies |
| Förderinformationen (1) |
Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989 Förderer ID Typ: ISNI Förderprogramm: EMPIR 2018 SI Broader Scope Titel der Förderung: 18SIB09: TEMMT: Traceability for electrical measurements at millimetre-wave and terahertz frequencies for communications and electronics technologies Förderungsnummer: 18SIB09 |
Zitierung
Allal, D., Arz, U., Phung, G. N., Gäumann, G., Gregory, A., Hudlicka, M., Kazemipour, A., Kleine-Ostmann, T., Phung, G. N., Premysl, M., Naftaly, M., Sakarya, H., Shang, X., Ulm, D., Wojciechowski, M., & Zagrajek, P. (2022). Comparison on material parameter measurements in the THz spectral range with optical, resonant and VNA based setups (Report No. 1514). Braunschweig: EURAMET.