Zugriffsnummer 48904
Dokumenttyp Zeitschriftenartikel Open Access Hybrid
Peer Review mit Peer Review
Sprache Deutsch
Titel Result of the MICROSCOPE weak equivalence principle test
Autor(in); Institution
Pierre Touboul, Pierre; ONERA, Palaiseau Cedex, FRANCE
Métris, Gilles; Université Cote d'Azur, Observatoire de la Cote d'Azur, CNRS, IRD, Valbonne, FRANCE
Rodrigues, Manuel; ONERA, Palaiseau Cedex, FRANCE
Bergé, Joel; ONERA, Palaiseau Cedex, FRANCE
Robert, Alain; CNES, Toulouse, FRANCE
Baghi, Quentin; Université Cote d'Azur, Observatoire de la Cote d'Azur, CNRS, IRD, Valbonne, FRANCE
André, Yves; CNES, Toulouse, FRANCE
Bedouet, Judicael; ONERA, Universit'e de Toulouse, Toulouse, FRANCE
Boulanger, Damien; ONERA, Palaiseau Cedex, FRANCE
Bremer, Stefanie; University of Bremen, ZARM, Center of Applied Space Technology and Microgravity, Bremen, GERMANY
Carle, Patrice; ONERA, Palaiseau Cedex, FRANCE
Chhun, Ratana; ONERA, Palaiseau Cedex, FRANCE
Christophe, Bruno; ONERA, Palaiseau Cedex, FRANCE
Cipolla, Valerio; CNES, Toulouse, FRANCE
Damour, Thibault; Institut des Hautes Etudes Scientifiques (IHES), Bures-sur-Yvette, FRANCE
Danto, Pascale; CNES, Toulouse, FRANCE
Demange, Louis; Université Cote d'Azur, Observatoire de la Cote d'Azur, CNRS, IRD, Valbonne, FRANCE
Dittus, Hansjörg; Deutsches Zentrum für Luft- und Raumfahrt (DLR), Köln Headquarters, Köln, GERMANY
Dhuicque, Océane; ONERA, Palaiseau Cedex, FRANCE
Fayet, Pierre; LPTENS, Ecole Normale Superieure (PSL Research University), Paris, FRANCE
Foulon, Bernard; ONERA, Palaiseau Cedex, FRANCE
Guidotti, Pierre-Yves; CNES, Toulouse, FRANCE
Hagedorn, Daniel; 5.5, Wissenschaftlicher Gerätebau, PTB-Braunschweig
Hardy, Emilie; ONERA, Palaiseau Cedex, FRANCE
Huynh, Phung-Anh; ONERA, Palaiseau Cedex, FRANCE
Kayser, Patrick; ONERA, Palaiseau Cedex, FRANCE
Lala, Stefanie; ONERA, Palaiseau Cedex, FRANCE
Lämmerzahl, Claus; University of Bremen, ZARM, Center of Applied Space Technology and Microgravity, Bremen, GERMANY
Lebat, Vinzenz; ONERA, Palaiseau Cedex, FRANCE
Liorzou, Francoise; ONERA, Palaiseau Cedex, FRANCE
List, Meike; University of Bremen, ZARM, Center of Applied Space Technology and Microgravity, Bremen, GERMANY
Löffler, Frank; 5.5, Wissenschaftlicher Gerätebau, PTB-Braunschweig
Panet, Isabelle; Institut Geographique National (IGN), Saint Mandé, FRANCE
Pernot-Borràs, Martin; ONERA, Palaiseau Cedex, FRANCE
Perraud, Laurent; CNES, Toulouse, FRANCE
Pires, Sandrine; CEA Saclay: Gif-sur-Yvette, Île-de-France, FRANCE
Pouilloux, Benjamin; CNES, Toulouse, FRANCE
Prieur, Pascal; CNES, Toulouse, FRANCE
Rebray, Alexandre; ONERA, Palaiseau Cedex, FRANCE
Reynaud, Serge; UPMC-Sorbonne Université, CNRS, ENS-PSL Research University, Laboratoire Kastler Brossel, Paris, FRANCE
Rievers, Benny; University of Bremen, ZARM, Center of Applied Space Technology and Microgravity, Bremen, GERMANY
Selig, Hans; University of Bremen, ZARM, Center of Applied Space Technology and Microgravity, Bremen, GERMANY
Serron, Laura; Université Cote d'Azur, Observatoire de la Cote d'Azur, CNRS, IRD, Valbonne, FRANCE
Sumner, Timothy; Imperial College London, Blackett Laboratory, London, UK
Tanguy, Nicolas; ONERA, Palaiseau Cedex, FRANCE
Torresi, Patrizia; CNES, Toulouse, FRANCE
Visser, Pieter; Delft University of Technology, Faculty of Aerospace Engineering, Delft, THE NETHERLANDS
Quelle/Jahr Classical and Quantum Gravity: 39 (2022), 20, 1 - 31
Artikelnummer 204009
ISSN 0264-9381 (PRINT) ; 1361-6382 (ONLINE)
DOI
Verlag Bristol: IOP Publishing
Freie Schlagworte MICROSCOPE ; Äquivalenzprinzips (EP) ; Gravitationstheorie ; Eötvös Parameter
Zusammenfassung The space mission MICROSCOPE dedicated to the test of the equivalence principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations (aA and aB) of two test masses in terms of the Eötvös parameter η(A,B) = 2 (aA-aB)/(aA+aB). No EP violation has been detected for two test masses, made from platinum and titanium alloys, in a sequence of 19 segments lasting from 13 to 198 h down to the limit of the statistical error which is smaller than 10-14 for η(Ti, Pt). Accumulating data from all segments leads to η(Ti, Pt) = [-1.5 ± 2.3 (stat) ± 1.5 (syst)] × 10-15 showing no EP violation at the level of 2.7 × 10-15 if we combine stochastic and systematic errors quadratically. This represents an improvement of almost two orders of magnitude with respect to the previous best such test performed by the Eöt-Wash group. The reliability of this limit has been verified by comparing the free falls of two test masses of the same composition (platinum) leading to a null Eötvös parameter with a statistical uncertainty of 1.1 × 10-15.
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Masse und abgeleitete Größen

Zitierung

Pierre Touboul, P., Métris, G., Rodrigues, M., Bergé, J., Robert, A., Baghi, Q., André, Y., Bedouet, J., Boulanger, D., Bremer, S., Carle, P., Chhun, R., Christophe, B., Cipolla, V., Damour, T., Danto, P., Demange, L., Dittus, H., Dhuicque, O., Fayet, P., Foulon, B., Guidotti, P.-Y., Hagedorn, D., Hardy, E., Huynh, P.-A., Kayser, P., Lala, S., Lämmerzahl, C., Lebat, V., Liorzou, F., List, M., Löffler, F., Panet, I., Pernot-Borràs, M., Perraud, L., Pires, S., Pouilloux, B., Prieur, P., Rebray, A., Reynaud, S., Rievers, B., Selig, H., Serron, L., Sumner, T., Tanguy, N., Torresi, P., & Visser, P. (2022). Result of the MICROSCOPE weak equivalence principle test. Classical and Quantum Gravity, 39(20), 1–31. https://doi.org/10.1088/1361-6382/ac84be

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag