Zugriffsnummer 48862
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Calibration-free-off-resonance-robust kT-Point Pulses for UHF body MRI
Autor(in); Institution
Aigner, Christoph Stefan; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Dietrich, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Krüger, Felix; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Lutz, Max; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Schmitter, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin; Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, GERMANY; Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, UNITED STATES
Quelle/Jahr 13th Annual Scientific Symposium on Clinical Needs, Research Promises and Technical Solutions in Ultrahigh Field MR:(2022), 4 S.
Konferenzangaben 13th Annual Scientific Symposium on Clinical Needs, Research Promises and Technical Solutions in Ultrahigh Field MR, Berlin, 9, September 2022, Germany
Freie Schlagworte MRI ; UHF ; parallel transmission
Zusammenfassung MRI in the human body at ultra-high fields (>7T) is highly challenging and typically limited by motion and strong inter-subject variations of the spatial flip-angle (FA) patterns. To overcome these limitations, subject-specific tailored parallel transmission (pTx) or pre-computed universal pulses (UPs) independent of the subject have been recently proposed. In contrast to RF shimming, however, dynamic pTx can be more susceptible to deviations in the main magnetic field (ΔB0), which can be substantial in 7T cardiac MRI. In this work, we demonstrate the feasibility of ΔB0-robust UPs across a 1400-Hertz frequency range that includes water and six fat frequencies to achieve homogeneous flip-angle (FA) distributions throughout the heart in the human body. Code for the pulse design and 3D B1+ datasets are provided under an open-source licence and could serve as a basis for new projects without the need to have access to a 7T scanner. .
Themenbereich der Metrologie Metrologie in der Medizin
Förderinformationen (1) Förderername: Deutsche Forschungsgemeinschaft (DFG)
Förderer ID: 0000 0001 2096 9829
Förderer ID Typ: ISNI
Förderprogramm: SCHM 2677/2-1 and GRK2260, BIOQIC

Zitierung

Aigner, C. S., Dietrich, S., Krüger, F., Lutz, M., & Schmitter, S. (2022). Calibration-free-off-resonance-robust kT-Point Pulses for UHF body MRI. 13th Annual Scientific Symposium on Clinical Needs, Research Promises and Technical Solutions in Ultrahigh Field MR, Berlin, 9, September 2022, Germany.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag