Titel Bottom-up approach for traceable calibration of tip geometry of stylus profilometer
Autor(in); Institution
Dai, Gaoliang; 5.2, Dimensionelle Nanometrologie, PTB-Braunschweig
Hu, Xiukun; 5.2, Dimensionelle Nanometrologie, PTB-Braunschweig
Degenhardt, Johannes; 5.2, Dimensionelle Nanometrologie, PTB-Braunschweig
Quelle/Jahr Surface Topography: Metrology and Properties: 10 (2022), 1, 1 - 12
Artikelnummer 015018
Availability [online only]
ISSN 2051-672X
DOI
Verlag Bristol: IOP Publishing
Freie Schlagworte stylus profilometry ; tip geometry ; calibration ; surface metrology ; form metrology ; atomic force microscopy (AFM) ; traceability
Zusammenfassung Anovel approach for accurate and traceable calibration of stylus tip geometry is introduced in the paper. The approach consists of several steps. Firstly, the geometry of anAFMtip is calibrated to a kind of line width standard whose geometry is traceably calibrated to the lattice constant of crystal silicon. Then, the stylus tip to be calibrated is measured by the calibratedAFMtip in an AFM, thus its tip geometry can be accurately determined after the contribution of theAFMtip geometry being corrected from the measuredAFMimage. After being calibrated, the stylus tip can be applied in measurements of vast microstructures and surfaces, where the measurement results can be in turn corrected using the characterized stylus tip geometry. In such a way, the stylus tip geometry and its measurement results can be finally traceable to the lattice constant of silicon, using this bottom-up approach. Detailed experimental examples are illustrated. For a stylus type RFTHB-50 studied in this paper, its tip radius is measured as 1.727 μm with a standard deviation of 0.007 μm. It is significantly smaller than its nominal value of 2 μm, indicating the need of the calibration. The application of calibrated stylus tip in measurements of microspheres is demonstrated. Compared to conventional tip characterization methods based on tip characterizers the proposed method has advantages of (i) no risk of damaging sharp edges of tip characterizers, (ii) capable of directly characterizing the 3D geometry of stylus tip, (iii) high accuracy.
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License

Zitierung

Dai, G., Hu, X., & Degenhardt, J. (2022). Bottom-up approach for traceable calibration of tip geometry of stylus profilometer. Surface Topography: Metrology and Properties, 10(1), 1–12. https://doi.org/10.1088/2051-672x/ac4f36

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag