Zugriffsnummer 45334
Dokumenttyp Zeitschriftenartikel Open Access Hybrid
Peer Review mit Peer Review
Sprache Englisch
Titel Three-dimensional static and dynamic parallel transmission of the human heart at 7 T
Autor(in); Institution
Aigner, Christoph Stefan; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Dietrich, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Schmitter, Sebastian; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Quelle/Jahr NMR in Biomedicine: 34 (2021), 3, 15 S.
Artikelnummer e4450
Availability [online only]
ISSN 1099-1492
DOI
Verlag New York, NY: Wiley
Freie Schlagworte heart ; kT-points ; parallel transmission ; 7 T
Zusammenfassung Three‐dimensional (3D) human heart imaging at ultra‐high fields is highly challenging due to respiratory and cardiac motion‐induced artifacts as well as spatially heterogeneous B1+ profiles. In this study, we investigate the feasibility of applying 3D flip angle (FA) homogenization targeting the whole heart via static phase‐only and dynamic kT‐point in vivo parallel transmission at 7 T. 3D B1+  maps of the thorax were acquired under free breathing in eight subjects to compute parallel transmission pulses that improve excitation homogeneity in the human heart. To analyze the number of kT‐points required, excitation homogeneity and radiofrequency (RF) power were compared using different regions of interest in six subjects with different body mass index (BMI) values of 20‐34 kg/m2 for a wide range of regularization parameters. One subset of the optimized subject‐specific pulses was applied in vivo on a 7 T scanner for six subjects in Cartesian 3D breath‐hold scans as well as in two subjects in a radial phase‐encoded 3D free‐breathing scan. Across all subjects, 3‐4 kT‐points achieved a good tradeoff between RF power and nominal FA homogeneity. For subjects with a BMI in the normal range, the 4 kT‐point pulses reliably improved the coefficient of variation by less than 10% compared with less than 25% achieved by static phase‐only parallel transmission. in vivo measurements on a 7 T scanner validated the B1+  estimations and the pulse design, despite neglecting ΔB0 in the optimizations and Bloch simulations. This study demonstrates in vivo that kT‐point pTx pulses are highly suitable for mitigating nominal FA heterogeneities across the entire 3D heart volume at 7 T. Furthermore, 3‐4 kT‐points demonstrate a practical tradeoff between nominal FA heterogeneity mitigation and RF power.
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Metrologie in der Medizin
Förderinformationen (1) Förderername: Deutsche Forschungsgemeinschaft (DFG)
Förderer ID: 0000 0001 2096 9829
Förderer ID Typ: ISNI
Förderprogramm: Grant/Award Nr SCHM 2677/2-1 ; GRK2260 BIOQIC

Zitierung

Aigner, C. S., Dietrich, S., & Schmitter, S. (2021). Three-dimensional static and dynamic parallel transmission of the human heart at 7 T. NMR in Biomedicine, 34(3), 15 S. https://doi.org/10.1002/nbm.4450