Titel Towards a calibration of laboratory setups for grazing incidence and total-reflection X-ray fluorescence analysis
Autor(in); Institution
Hönicke, Philipp; 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Waldschläger, Ulrich; Bruker Nano GmbH, Berlin, GERMANY
Wiesner, Thomas; 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Krämer, Markus; AXO DRESDEN GmbH, Dresden, GERMANY
Beckhoff, Burkhard; 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Quelle/Jahr Spectrochimica Acta B: 174 (2020), 7 S.
Artikelnummer 106009
ISSN 0584-8547 (PRINT) ; 1873-3565 (ONLINE)
DOI
Verlag Amsterdam: Elsevier
Freie Schlagworte Gracing incidence X-ray fluorescence ; Laboratory setup ; Solid angle characterization
Zusammenfassung Grazing-Incidence X-ray fluorescence (GIXRF) analysis, which is closely related to total-reflection XRF, is a very powerful technique for the in-depth analysis of many types of technologically relevant samples, e.g. nanoparticle depositions, shallow dopant profiles, thin layered samples or even well-ordered nanostructures. However, the GIXRF based determination of the depth-dependent information about the sample is usually based on a modeling of the experimental data. This requires profound knowledge of the geometrical parameters of the setup employed, especially the incident beam profile as well as the detector aperture parameters. Together they determine the incident angle dependent so-called effective solid angle of detection which must be known in order to model any experimental data set. In this work, we demonstrate how these instrumental parameters, which are typically not known with sufficient accuracy, can be determined using dedicated experiments with a well-known calibration sample. In addition, this paves the way for a full calibration of the setup, as also information about other parameters, e.g. the incident photon flux is gained. Here, we are using a commercially available instrument for this demonstration but the principle can also be applied for other GIXRF setups.
Themenbereich der Metrologie Photometrie und Radiometrie

Zitierung

Hönicke, P., Waldschläger, U., Wiesner, T., Krämer, M., & Beckhoff, B. (2020). Towards a calibration of laboratory setups for grazing incidence and total-reflection X-ray fluorescence analysis. Spectrochimica Acta B, 174, 7 S. https://doi.org/10.1016/j.sab.2020.106009