Titel Measurement of the absolute number of photons of the hard X-ray beamline at the Linac Coherent Light Source
Autor(in); Institution
Song, Sanghoon; Linac Coherent Light Source, Menlo Park, USA
Alonso-Mori, Roberto; Linac Coherent Light Source, Menlo Park, USA
Chollet, Matthieu; Linac Coherent Light Source, Menlo Park, USA
Feng, Yiping; Linac Coherent Light Source, Menlo Park, USA
Glownia, James M.; Linac Coherent Light Source, Menlo Park, USA
Lemke, Henrik T.; Linac Coherent Light Source, Menlo Park, USA
Sikorski, Marcin; Linac Coherent Light Source, Menlo Park, USA
Zhu, Diling; Linac Coherent Light Source, Menlo Park, USA
Moeller, Stefan; Linac Coherent Light Source, Menlo Park, USA
Lee, Hae Ja; Linac Coherent Light Source, Menlo Park, USA
Hunter, Mark S.; Linac Coherent Light Source, Menlo Park, USA
Carini, Gabriella; Brookhaven National Laboratory, Upton, NY, USA
Tiedtke, Kai; Deutsches Elektronen-Synchrotron, Hamburg, GERMANY
Jastrow, Ulf; Deutsches Elektronen-Synchrotron, Hamburg, GERMANY
Sorokin, Andrey; Deutsches Elektronen-Synchrotron, Hamburg, GERMANY
Richter, Mathias; 7, Temperatur und Synchrotronstrahlung, PTB-Berlin
Owada, Shigeki; RIKEN, Hyogo, JAPAN
Tono, Kensuke; RIKEN, Hyogo, JAPAN
Saito, Norio; RIKEN, Hyogo, JAPAN
Tanaka, Takahiro; RIKEN, Hyogo, JAPAN
Kato, Masahiro; RIKEN, Hyogo, JAPAN
Yabashi, Makina; RIKEN, Hyogo, JAPAN
Robert, Aymeric; Linac Coherent Light Source, Menlo Park, USA
Quelle/Jahr Journal of Synchrotron Radiation: 26 (2019), 2, 320 - 327
ISSN 0909-0495 (PRINT) ; 1600-5775 (ONLINE)
DOI
Verlag Oxford: Blackwell
Freie Schlagworte FEL ; hard X-rays ; absolute intensity
Zusammenfassung X-ray free-electron lasers provide intense pulses of coherent X-rays with a short pulse duration. These sources are chaotic by nature and therefore, to be used at their full potential, require that every X-ray pulse is characterized in terms of various relevant properties such as intensity, photon energy, position and timing. Diagnostics are for example installed on an X-ray beamline to specifically monitor the intensity of individual X-ray pulses. To date, these can however only provide a single-shot value of the relative number of photons per shot. Here are reported measurements made in January 2015 of the absolute number of photons in the hard X-ray regime at LCLS which is typically 3.5  1011 photons shot1 between 6 and 9.5 keV at the X-ray Pump–Probe instrument. Moreover, an average transmission of ~62% of the hard X-ray beamline over this energy range is measured and the third-harmonic content of ~0.47% below 9 keV is characterized.
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Photometrie und Radiometrie

Zitierung

Song, S., Alonso-Mori, R., Chollet, M., Feng, Y., Glownia, J. M., Lemke, H. T., Sikorski, M., Zhu, D., Moeller, S., Lee, H. J., Hunter, M. S., Carini, G., Tiedtke, K., Jastrow, U., Sorokin, A., Richter, M., Owada, S., Tono, K., Saito, N., Tanaka, T., Kato, M., Yabashi, M., & Robert, A. (2019). Measurement of the absolute number of photons of the hard X-ray beamline at the Linac Coherent Light Source. Journal of Synchrotron Radiation, 26(2), 320–327. https://doi.org/10.1107/s1600577519000250