Zugriffsnummer 45101
Dokumenttyp Konferenzartikel in Zeitschrift Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Evaluation of spatio-temporal resolution of MPI scanners with a dynamic bolus phantom
Autor(in); Institution
Dutz, S.; Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, GERMANY
Stang, A.; Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, GERMANY
Wöckel, L.; Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, GERMANY
Kosch, Olaf; 8.2, Biosignale, PTB-Berlin
Vogel, P.; Department of Experimental Physics 5 (Biophysics), University of Würzburg, Würzburg, GERMANY
Grüttner, C.; micromod Partikeltechnologie GmbH, Rostock, GERMANY
Behr, V. C.; Department of Experimental Physics 5 (Biophysics), University of Würzburg, Würzburg, GERMANY
Wiekhorst, Frank; 8.2, Biosignale, PTB-Berlin
Quelle/Jahr International Journal on Magnetic Particle Imaging: 6 (2020), 2, (Suppl. 1), 3 pages
Artikelnummer 2009011
ISSN 2365-9033 (PRINT) ; 2365-9033 (ONLINE)
DOI
Verlag Lübeck: Infinite Science
Konferenzangaben 10th International Workshop on Magnetic Particle Imaging (IWMPI2020), Virtual Conference, 7-8, September, 2020
Zusammenfassung Magnetic particle imaging (MPI) is a tomographic imaging method to determine the spatial distribution of magnetic nanoparticles (MNP) within a defined volume. To evaluate the spatio-temporal resolution of existing MPI scanners, enabling a comparison of the performance of different setups, we developed dynamic MPI measurement phantoms. These segmented flow phantoms consist of a bolus of ferrofluid tracer material, pumped through a tube system. Using a hydrophobic organic carrier oil, cylindrically shaped bolus of different diameter, length,MNPconcentrations, and flowvelocity can be emulated. Moving boluseswere imaged byMPI and the correlation of spatial resolution und velocity of the bolus was investigated. For all bolus dimension and flow velocity combinations, for increasing bolus velocity and decreasing bolus volume a decreasing spatial resolution and increasing blurring with was observed. [Conference did take place as virtual conference because of Covid-19 virus pandemic]
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Metrologie in der Medizin

Zitierung

Dutz, S., Stang, A., Wöckel, L., Kosch, O., Vogel, P., Grüttner, C., Behr, V. C., & Wiekhorst, F. (2020). Evaluation of spatio-temporal resolution of MPI scanners with a dynamic bolus phantom. International Journal on Magnetic Particle Imaging, 6(2, (Suppl. 1)), 3 pages. https://doi.org/10.18416/ijmpi.2020.2009011

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag