Zugriffsnummer 45054
Dokumenttyp Zeitschriftenartikel Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Revisiting 129Xe electric dipole moment measurements applying a new global phase fitting approach
Autor(in); Institution
Liu, Tianhao; 8.2, Biosignale, PTB-Berlin; Department of Electrical Engineering, Harbin Institute of Technology, Harbin, CHINA
Rolfs, Katharina; 8.2, Biosignale, PTB-Berlin
Fan, Isaac; 8.2, Biosignale, PTB-Berlin
Haude, Sophia; 8.2, Biosignale, PTB-Berlin
Kilian, Wolfgang; 8.1, Biomedizinische Magnetresonanz, PTB-Berlin
Li, L.; Department of Electrical Engineering, Harbin Institute of Technology, Harbin, CHINA
Schnabel, Allard; 8.2, Biosignale, PTB-Berlin
Voigt, Jens; 8.2, Biosignale, PTB-Berlin
Trahms, Lutz; 8.2, Biosignale, PTB-Berlin
Quelle/Jahr New Journal of Physics: 23 (2021), 17 S.
Artikelnummer 063076
ISSN 2470-0010 (PRINT) ; 2470-0029 (ONLINE)
DOI
URL
Verlag Bristol: IOP
Klassifikationscode PACS: 95.55.Sh ; PACS: 93.90.+y ; PACS: 13.15.+g
Freie Schlagworte electric dipole moment ; data analysis ; quantum measurement ; Monte-Carlo analysis ; CP-violation
Zusammenfassung By measuring the nuclear magnetic spin precession frequency of polarized 129Xe and ³He, we previously reported [Phys. Rev. Lett. 123, 143003(2019)] a new upper limit on the 129Xe atomic electric dipole moment (EDM).Here, we propose a new evaluation method called global phase fitting (GPF) for analyzing the continuous phase development of ³He-129Xe comagnetometer oscillation. The Cramer-Rao Lower Bound on the 129Xe EDM for the GPF method is theoretically derived and verified with Monte-Carlo studies. Applying the GPF to the same data set used for our previous analysis leads to a consistent result with smaller statistical uncertainty. By optimizing the analysis parameters and adding data that could not be analyzed with the previous method, we obtained the result of dA(129Xe) =1.08±3.13(stat) ±1.83(syst)×10-28ecm. The updated null result can be interpreted as anew upper limit of dA(129Xe) (7.4×10-28ecm at the 95% C.L., almost a factor of 2smaller than our preceding result and roughly a magnitude lower than the result of 2001. Auch veröffentlicht in arXiv: https://arxiv.org/abs/2008.07975
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Metrologie in der Medizin

Zitierung

Liu, T., Rolfs, K., Fan, I., Haude, S., Kilian, W., Li, L., Schnabel, A., Voigt, J., & Trahms, L. (2021). Revisiting ¹²⁹Xe electric dipole moment measurements applying a new global phase fitting approach. New Journal of Physics, 23, 17 S. https://doi.org/10.1088/1367-2630/ac09ca

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag