Zugriffsnummer 44948
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Update on the future BIPM on-site comparison program for Josephson ac voltage standards
Autor(in); Institution
Solve, Stephane; Bureau International des Poids et Mesures (BIPM), Sevres, FRANCE
Kim, Mun-Seog; Korea Research Institute of Standards and Science (KRISS), Daejeon, REPUBLIC OF KOREA
Palafox, Luis; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Behr, Ralf; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Budovxky, Ilya; National Measurement Institute Australia, Lindfield, AUSTRALIA
Gubler, Gleb; D.I. Mendeleyev Institute for Metrology (VNIIM), Saint Petersburg, RUSSIA
Quelle/Jahr 2020 Conference on Precision Electromagnetic Measurements (CPEM 2020):(2020), 316 - 317
ISSN 2160-0171 (ONLINE) ; 0589-1485 (POD)
ISBN 978-1-7281-5898-3 (PDF) ; 978-1-7281-5899-0 (PoD)
DOI
Verlag New York, NY: IEEE
Konferenzangaben Conference on Precision Electromagnetic Measurements (CPEM 2020), Virtual Conference, 24-28, August, 2020
Freie Schlagworte AC voltage measurement standards ; Programmable Josephson Voltage Standards ; Differential Sampling ; On-site-comparison
Zusammenfassung BIPM has continued its program of pilot studies by investigating the possibilities to derive a protocol for Josephson Voltage Standard comparisons of ac voltages up to 7 V rms at low frequencies (< 1 kHz) based on the differential sampling technique. We have confirmed that an agreement within a few parts in 107 can typically be achieved using a commercial calibrator as a transfer standard. We have also investigated other ac generators as possible candidates for a stable transfer standard. The sensitivity of the rms voltage measurement result to key parameters (filtering at the output of the ac source, grounding of the measurement setup, acquisition software, etc.) has been evaluated. The possibility of a measurement system (meter and software) that performs a full sampling of the ac source signal in addition to the differential sampling has also been investigated. It offers the possibility to follow the drift of the source.
Themenbereich der Metrologie Elektrizität und Magnetismus

Zitierung

Solve, S., Kim, M.-S., Palafox, L., Behr, R., Budovxky, I., & Gubler, G. (2020). Update on the future BIPM on-site comparison program for Josephson ac voltage standards. Conference on Precision Electromagnetic Measurements (CPEM 2020), Virtual Conference, 24-28, August, 2020. https://doi.org/10.1109/cpem49742.2020.9191727

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag