Zugriffsnummer 44741
Dokumenttyp Zeitschriftenartikel Open Access Hybrid
Peer Review mit Peer Review
Sprache Englisch
Titel Comparing the adiabatic and isothermal pressure dependence of the index of refraction in a drop-weight apparatus
Autor(in); Institution
Slanina, Oliver; 1.3, Geschwindigkeit, PTB-Braunschweig
Quabis, Susanne; 1.3, Geschwindigkeit, PTB-Braunschweig
Derksen, Stanislaw; 1.3, Geschwindigkeit, PTB-Braunschweig
Herbst, Jörg; 1.3, Geschwindigkeit, PTB-Braunschweig
Wynands, Robert; 1.3, Geschwindigkeit, PTB-Braunschweig
Quelle/Jahr Applied Physics B: 126 (2020), 11, 10 S.
ISSN 0946-2171 (PRINT) ; 1432-0649 (ONLINE)
DOI
Verlag Berlin: Springer
Klassifikationscode PACS: 07.35.+k ; PACS: 47.80.Fg ; PACS: 62.50.-p ; PACS: 92.60.hv
Freie Schlagworte pressure transducer ; pressure sensor ; dynamic calibration ; pressure standard ; sebacate ; glycerol water
Zusammenfassung We have investigated the difference between adiabatic and isothermal compression of liquids by an impacting weight, as observed in the resulting change to the index of refraction. The liquids examined were sebacate, glycerol, and water. For practical reasons, sebacate is best suited for the use of a drop-weight apparatus as a metrologically traceable calibration facility for dynamic pressure. We find that its optical properties under adiabatic and isothermal compression can be converted into each other using literature values of its thermodynamic properties. Care has to be taken to avoid cavitation-like effects, an observation that might need to be taken into account for other methods of generating short pressure pulses in the hundreds-of-MPa range.
Relation
Kostenfreier Zugang Open Access Hybrid
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Akustik, Ultraschall, Beschleunigung
Förderinformationen (1) Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989
Förderer ID Typ: ISNI
Förderprogramm: EMPIR 2017 Industry
Titel der Förderung: 17IND07: DynPT: Development of measurement and calibration techniques for dynamic pressures and temperatures
Förderungsnummer: 17IND07

Zitierung

Slanina, O., Quabis, S., Derksen, S., Herbst, J., & Wynands, R. (2020). Comparing the adiabatic and isothermal pressure dependence of the index of refraction in a drop-weight apparatus. Applied Physics B, 126(11), 10 S. https://doi.org/10.1007/s00340-020-07519-z