Zugriffsnummer 44696
Dokumenttyp Zeitschriftenartikel Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Characterization of the secondary neutron field produced in a thick aluminum shield by 1 GeV/u 56Fe ions using TLD-based ambient dosimeters
Autor(in); Institution
Boscolo, Daria; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY
Scognamiglio, Daniela; University of Naples Parthenope, Neapel, ITALY; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY
Horst, Felix; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY; Technische Hochschule Mittelhessen, Giessen, GERMANY
Weber, Uli; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY
Schuy, Christoph; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY
Durante, Marco; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY; Darmstadt University of Technology, Darmstadt, GERMANY
La Tessa, Chiara; Trento Institute for Fundamental Physics and Applications, University of Trento, Trento, ITALY
Kozlova, Ekaterina; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY
Sokolov, Alexey; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY
Diescu, Irina; Horia Hulubei National Institute for Research and Development in Physics and Nuclear Engineering (IFIN-HH), Bucharest, ROMANIA
Radon, Torsten; GSI Helmholtz Center for Heavy Ion Research, Darmstadt, GERMANY
Radeck, Désirée; 6.4, Neutronenstrahlung, PTB-Braunschweig
Zboril, Miroslav; 6.4, Neutronenstrahlung, PTB-Braunschweig
Quelle/Jahr Frontiers in Physics: 8 (2020), 1 - 9
Artikelnummer 365
Availability [online only]
ISSN 2296-424X
DOI
Verlag Lausanne: Frontiers Media SA
Freie Schlagworte Space radiation shielding ; Neutron production ; Ion fragmentation ; TLD ; Neutron detectors ; monte carlo
Zusammenfassung The neutron ambient dose equivalent induced by galactic cosmic ray-like (1 GeV/u 56Fe) radiation stopped in a thick aluminum shield was measured at different angles with GSI neutron ball, the standard TLD (thermoluminescent dosimeters) based neutron dosimeter for area monitoring at the GSI facility. In order to measure reliably at large angles, a modified version of the GSI ball, including a set of three more sensitive TLD600H/700H cards, instead of one standard TLD600/700, cards was used. The modified GSI balls were calibrated in neutron reference fields of 241Am-Be(alpha,n) available at the Physikalisch-Technische Bundesanstalt (PTB). The neutron ambient dose equivalent was measured at 5 different angles (15, 40, 90, 115 and 130 degree) with respect to the beam direction and compared to the calculated detector response and ambient neutron dose equivalent results from FLUKA simulations. The dosimeter readings were corrected for signal contributions coming from secondary charged particles. An agreement within 15 % was found between the measured and calculated GSI ball response and an agreement within 30 % was found between experiments and calculated neutron dose equivalents.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Ionisierende Strahlung
Forschungsprojekt Investigations into Biological Effects of Radiation
Förderinformationen (1) Förderername: European Space Agency (ESA)
Förderprogramm: IBER 17

Zitierung

Boscolo, D., Scognamiglio, D., Horst, F., Weber, U., Schuy, C., Durante, M., La Tessa, C., Kozlova, E., Sokolov, A., Diescu, I., Radon, T., Radeck, D., & Zboril, M. (2020). Characterization of the secondary neutron field produced in a thick aluminum shield by 1 GeV/u 56Fe ions using TLD-based ambient dosimeters. Frontiers in Physics, 8, 1–9. https://doi.org/10.3389/fphy.2020.00365

Exportieren