Zugriffsnummer 44664
Dokumenttyp Zeitschriftenartikel
Peer Review mit Peer Review
Sprache Englisch
Titel The Chicago Water Isotope Spectrometer (ChiWIS-lab): A tunable diode laser spectrometer for chamber-based measurements of water vapor isotopic evolution during cirrus formation
Autor(in); Institution
Sarkozy, Laszlo C.; University of Chicago, Chicago, USA
Clouser, Benjamin W.; University of Chicago, Chicago, USA
Lamb, Kara D.; University of Chicago, Chicago, USA
Stutz, Eric J.; University of Chicago, Chicago, USA
Saathoff, Harald; Karlsruhe Institute of Technology, Karlsruhe, GERMANY
Möhler, Ottmar; Karlsruhe Institute of Technology, Karlsruhe, GERMANY
Ebert, Volker; 3.4, Analytische Chemie der Gasphase, PTB-Braunschweig
Moyer, Elisabeth J.; University of Chicago, Chicago, USA
Quelle/Jahr Review of Scientific Instruments: 91 (2020), 1 - 16
Artikelnummer 045120
ISSN 0034-6748 (PRINT) ; 1089-7623 (ONLINE)
DOI
Verlag Melville, NY: AIP
Zusammenfassung We describe a new tunable diode laser (TDL) absorption instrument, the Chicago Water Isotope Spectrometer, designed for measurements ofvapor-phase water isotopologues in conditions characteristic of the upper troposphere [190-235 K temperature and 2-500 parts per millionvolume (ppmv) water vapor]. The instrument is primarily targeted for measuring the evolving ratio of HDO/H2O during experiments in the "Aerosol Interaction and Dynamics in the Atmosphere" (AIDA) cloud chamber. The spectrometer scans absorption lines of both H2O and HDO near the 2.64 μm wavelength in a single current sweep, increasing the accuracy of isotopic ratio measurements. At AIDA, the instrumentis configured with a 256-m path length White cell forin situmeasurements, and effective sensitivity can be augmented by enhancing the HDO content of chamber water vapor by an order of magnitude. The instrument has participated to date in the 2012-2013 IsoCloud campaignsstudying isotopic partitioning during the formation of cirrus clouds and in the AquaVIT-II instrument intercomparison campaign. Realized precisions for 1-s measurements during these campaigns were 22 ppbv for H2O and 16 ppbv for HDO, equivalent to relative precisions of lessthan 0.5% for each species at 8 ppmv water vapor. The 1-s precision of the [HDO]/[H2O] ratio measurement ranged from 1.6‰ to 5.6‰ over the range of experimental conditions. H2O measurements showed agreement with calculated saturation vapor pressure to within 1% inconditions of sublimating ice and agreement with other AIDA instruments (the AIDA SP-APicT reference TDL instrument and an MBW373LX chilled mirror hygrometer) to within 2.5% and 3.8%, respectively, over conditions suitable for all instruments (temperatures from 204 K to 234 K and H2O content equivalent to 15-700 ppmv at 200 hPa)
Themenbereich der Metrologie Metrologie in der Chemie und Stoffeigenschaften

Zitierung

Sarkozy, L. C., Clouser, B. W., Lamb, K. D., Stutz, E. J., Saathoff, H., Möhler, O., Ebert, V., & Moyer, E. J. (2020). The Chicago Water Isotope Spectrometer (ChiWIS-lab): A tunable diode laser spectrometer for chamber-based measurements of water vapor isotopic evolution during cirrus formation. Review of Scientific Instruments, 91, 1–16. https://doi.org/10.1063/1.5139244

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag