| Zugriffsnummer | 44644 |
| Dokumenttyp | Zeitschriftenartikel |
| Peer Review | mit Peer Review |
| Sprache | Englisch |
| Titel | Non-contact temperature measurement at the Physikalisch-Technische Bundesanstalt (PTB) |
| Autor(in); Institution |
Müller, Ingmar; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Adibekyan, Albert; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Anhalt, Klaus; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Baltruschat, Christoph; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Gutschwager, Berndt; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
König, Sebastian; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Kononogova, Elena; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Monte, Christian; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Reiniger, Max; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Schiller, Stephan; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Taubert, Richard Dieter; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Urban, David; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Hollandt, Jörg; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
|
| Quelle/Jahr | Quantitative InfraRed Thermography: 18 (2021), 3, 187 - 212 |
| ISSN | 1768-6733 (PRINT) ; 2116-7176 (ONLINE) |
| DOI | |
| Verlag | Cachan Cedex: Taylor & Francis |
| Freie Schlagworte | Metrology ; thermography ; radiometry ; radiation thermometry ; calibration |
| Zusammenfassung | At the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of the Federal Republic of Germany, the traceability of non-contact temperature measurement to the International Temperature Scale (ITS-90) is realised without gaps over a temperature range from −170°C to 3000°C. In this paper the main calibration facilities for the calibration of radiation thermometers at temperatures above 1000°C and measurement of spectral radiance, the calibration of radiation thermometers at temperatures below 1000°C, the calibration of infrared thermographic cameras together with a method developed at PTB to correct the non-uniform response of sensor arrays, the calibration of infrared hyperspectral imagers for remote sensing, and emissivity measurement for industry and remote sensing are described. These facilities are tailored for different temperature ranges and different spectral ranges to meet the demand of industry and research for precise, practical non-contact temperature measurement. |
| Themenbereich der Metrologie | Photometrie und Radiometrie |
| Innovationscluster | Umwelt und Klima |
Zitierung
Müller, I., Adibekyan, A., Anhalt, K., Baltruschat, C., Gutschwager, B., König, S., Kononogova, E., Monte, C., Reiniger, M., Schiller, S., Taubert, R. D., Urban, D., & Hollandt, J. (2021). Non-contact temperature measurement at the Physikalisch-Technische Bundesanstalt (PTB). Quantitative InfraRed Thermography, 18(3), 187–212. https://doi.org/10.1080/17686733.2020.1734392