Zugriffsnummer 44233
Dokumenttyp Zeitschriftenartikel Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Widening and distortion of the particle energy distribution by chromaticity in quasi-isochronous rings
Autor(in); Institution
Deng, X. J.; Department of Engineering Physics, Tsinghua University, Beijing, CHINA
Klein, Roman; 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Chao, A. W.; Institute for Advanced Study, Tsinghua University, Beijing, CHINA; SLAC National Accelerator Laboratory, Stanford University, Stanford, California, USA
Hoehl, Arne; 7.1, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Huang, W. H.; Department of Engineering Physics, Tsinghua University, Beijing, CHINA
Li, J.; Helmholtz-Zentrum Berlin (HZB), Berlin, GERMANY
Lubeck, Janin; 7.2, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Petenev, Y.; Helmholtz-Zentrum Berlin (HZB), Berlin, GERMANY
Ries, M.; Helmholtz-Zentrum Berlin (HZB), Berlin, GERMANY
Seiler, I.; Helmholtz-Zentrum Berlin (HZB), Berlin, GERMANY
Tang, C. X.; Department of Engineering Physics, Tsinghua University, Beijing, CHINA
Feikes, J.; Helmholtz-Zentrum Berlin (HZB), Berlin, GERMANY
Quelle/Jahr Physical Review Accelerators and Beams: 23 (2020), 4, 8 S.
Artikelnummer 044001
Availability [online-only]
ISSN 2469-9888 ; 1098-4402
DOI
Verlag [s.l.]: The American Physical Society
Zusammenfassung This paper reports the observation of beam energy widening and distortion from Gaussian due to a nonvanishing horizontal chromaticity at a quasi-isochronous storage ring. The result originates from an average path-length dependence on the betatron oscillation amplitudes, which is intimately correlated to the transverse chromaticities. It is the first experimental validation of the impact of such a nonlinear transverse-longitudinal coupling effect on the equilibrium beam characteristics in a storage ring. The results could be important for quasi-isochronous rings, steady-state microbunching, nonscaling fixed-field alternate gradient accelerators, etc., where very small momentum compaction or large chromaticity is required.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Photometrie und Radiometrie

Zitierung

Deng, X., Klein, R., Chao, A. W., Hoehl, A., Huang, W. H., Li, J., Lubeck, J., Petenev, Y., Ries, M., Seiler, I., Tang, C. X., & Feikes, J. (2020). Widening and distortion of the particle energy distribution by chromaticity in quasi-isochronous rings. Physical Review Accelerators and Beams, 23(4), 8 S. https://doi.org/10.1103/physrevaccelbeams.23.044001

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag