Zugriffsnummer 43848
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Frequency measurement of the hyperfine splitting of sup.171YB+ ions stored in a Paul trap
Autor(in); Institution
Bauch, Andreas; 4.41, Zeiteinheit, PTB-Braunschweig
Schnier, D.; 4.41, Zeiteinheit, PTB-Braunschweig
Tamm, Christian; 4.41, Zeiteinheit, PTB-Braunschweig
Quelle/Jahr 7th European Frequency and Time Forum : Neuchâtel, Switzerland, March 16-18, 1993:(1993), 583 - 588
Verlag Neuchâtel: FSRM
Konferenzangaben 7th European Frequency and Time Forum Neuchâtel, Neuchâtel, 16-18, March, 1993, Switzerland
Freie Schlagworte trapped ions ; ytterbium ; optical and microwave spectroscopy
Zusammenfassung A precision measurement of the ground state hyperfine splitting frequency of sup.171YB+ ions is described in which buffer gas cooled ion clouds stored in a Paul trap and a reference oscillator locked to an active hydrogen maser are used. The final value is f0 = 12 642 812 118,471 Hz. The sum of systematic and statistical measurement uncertainties (1σ) is evaluated to be 9 mHz. The uncertainties are mainly caused by the determination of the frequency shifts resulting from the second-order Doppler effect, the quadratic Stark effect, and collisions with buffer gas atoms.

Zitierung

Bauch, A., Schnier, D., & Tamm, C. (1993). Frequency measurement of the hyperfine splitting of sup.171YB⁺ ions stored in a Paul trap. 7th European Frequency and Time Forum Neuchâtel, Neuchâtel, 16-18, March, 1993, Switzerland.