Zugriffsnummer 43285
Dokumenttyp Zeitschriftenartikel
Peer Review mit Peer Review
Sprache Englisch
Titel The equilibrium liquidus temperatures of rhenium-carbon, platinum-carbon and cobalt-carbon eutectic alloys
Autor(in); Institution
Lowe, D. H.; National Physical Laboratory (NPL), Teddington, UK
Todd, A. D. W.; National Reseach Council Canada (NRC), Ottawa, CANADA
Van den Bossche, R.; University of Surrey, Guildford, UK
Bloembergen, P.; National Institute of Metrology (NIM), Beijing, CHINA
Anhalt, Klaus; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Ballico, M.; National Measurement Institute Australia (NMIA), West Lindfield, AUSTRALIA
Bourson, F.; Laboratoire commen de métrology (LNE-CNAM), Saint-Denis, FRANCE
Briaudeau, S.; Laboratoire commen de métrology (LNE-CNAM), Saint-Denis, FRANCE
Campos, J.; Spanish National Research Council (CSIS), Madrid, SPAIN
Cox, M. G.; National Physical Laboratory (NPL), Teddington, UK
del Campo, D.; Centro Espanol de Metrologia (CEM), Tres Cantos, SPAIN
Dury, M. R.; National Physical Laboratory (NPL), Teddington, UK
Gavrilov, I.; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Grigoryeva, I.; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Hernanz, M. L.; Spanish National Research Council (CSIS), Madrid, SPAIN
Jahan, F.; National Measurement Institute Australia (NMIA), West Lindfield, AUSTRALIA
Khlevnoy, B.; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Khromchenko, V.; National Institute of Standards and Technology (NIST), Gaithersburg, USA
Lu, X.; National Institute of Metrology (NIM), Beijing, CHINA
Machin, G.; National Physical Laboratory (NPL), Teddington, UK
Mantilla, J. M.; Centro Espanol de Metrologia (CEM), Tres Cantos, SPAIN
Martin, M. J.; Centro Espanol de Metrologia (CEM), Tres Cantos, SPAIN
McEvoy, H. C.; National Physical Laboratory (NPL), Teddington, UK
Rougié, B.; Laboratoire commen de métrology (LNE-CNAM), Saint-Denis, FRANCE
Sadli, M.; Laboratoire commen de métrology (LNE-CNAM), Saint-Denis, FRANCE
Salim, S. G. R.; Laboratoire commen de métrology (LNE-CNAM), Saint-Denis, FRANCE; National Institute for Standards (NIS), El-Haram, EGYPT
Sasajima, N.; National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, JAPAN
Taubert, Richard Dieter; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
dan der Ham, E.; National Measurement Institute Australia (NMIA), West Lindfield, AUSTRALIA
Wang, T.; National Institute of Metrology (NIM), Beijing, CHINA
Wei, D.; National Institute of Metrology (NIM), Beijing, CHINA
Whittam, A.; National Physical Laboratory (NPL), Teddington, UK
Wilthan, Boris; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Woods, D. J.; National Reseach Council Canada (NRC), Ottawa, CANADA
Woodward, J. T.; National Institute of Standards and Technology (NIST), Gaithersburg, USA
Woolliams, E. R.; National Physical Laboratory (NPL), Teddington, UK
Yamada, Y.; National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, JAPAN
Yamaguchi, Y.; National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, JAPAN
Yoon, H. W.; National Institute of Standards and Technology (NIST), Gaithersburg, USA
Yuan, Z.; National Institute of Metrology (NIM), Beijing, CHINA
Quelle/Jahr Metrologia: 54 (2017), 3, 390 - 398
Availability [online only]
ISSN 1681-7575 (online) ; 0026-1394 (print)
DOI
Verlag Bristol: IOP Publishing
Zusammenfassung The eutectic alloys rhenium–carbon, platinum–carbon and cobalt–carbon have been proposed as reference standards for thermometry, with temperature and uncertainty values specified within the mise en pratique of the definition of the kelvin. These alloys have been investigated in a collaboration of eleven national measurement institutes and laboratories. Published results reported the point-of-inflection in the melting curve with extremely low uncertainties. However, to be considered as standards it is necessary to stipulate what phenomenon a temperature value has been ascribed to; specifically, this should be a thermodynamic state. Therefore, the data have been further evaluated and the equilibrium liquidus temperatures determined based on a consideration of limits and assuming a rectangular probability distribution. The values are: for rhenium–carbon 2747.91  ±  0.44 K, for platinum–carbon 2011.50  ±   0.22 K and for cobalt–carbon 1597.48  ±  0.14 K, with uncertainties at approximately a 95% coverage probability. It is proposed that these values could be used as the basis of thermodynamic temperature measurement at high temperatures (above 1300 K).

Zitierung

Lowe, D. H., Todd, A. D. W., Van den Bossche, R., Bloembergen, P., Anhalt, K., Ballico, M., Bourson, F., Briaudeau, S., Campos, J., Cox, M. G., del Campo, D., Dury, M. R., Gavrilov, I., Grigoryeva, I., Hernanz, M. L., Jahan, F., Khlevnoy, B., Khromchenko, V., Lu, X., Machin, G., Mantilla, J. M., Martin, M. J., McEvoy, H. C., Rougié, B., Sadli, M., Salim, S. G. R., Sasajima, N., Taubert, R. D., dan der Ham, E., Wang, T., Wei, D., Whittam, A., Wilthan, B., Woods, D. J., Woodward, J. T., Woolliams, E. R., Yamada, Y., Yamaguchi, Y., Yoon, H. W., & Yuan, Z. (2017). The equilibrium liquidus temperatures of rhenium-carbon, platinum-carbon and cobalt-carbon eutectic alloys. Metrologia, 54(3), 390–398. https://doi.org/10.1088/1681-7575/aa6eeb

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag