Titel Validation of three-component wind lidar sensor for traceable highly resolved wind vector measurements
Autor(in); Institution
Oertel, Stefan; 1.4, Gase, PTB-Braunschweig
Eggert, Michael; 1.4, Gase, PTB-Braunschweig
Gutsmuths, Christian; 1.4, Gase, PTB-Braunschweig
Wilhelm, Paul; 1.4, Gase, PTB-Braunschweig
Müller, Harald; 1.4, Gase, PTB-Braunschweig
Többen, Helmut; 1.4, Gase, PTB-Braunschweig
Quelle/Jahr Journal of Sensors and Sensor Systems:(2019), 8, 9 - 17
ISSN 2194-8771 (PRINT) ; 2194-878X (ONLINE)
DOI
Verlag Göttingen: Copernicus Publications
Zusammenfassung Conventional monostatic wind lidar (light detection and ranging) systems are well-established wind speed remote sensing devices in the field of wind energy that provide reliable measurement results for flat terrain and homogeneous wind fields. These conventional wind lidar systems use a common transmitting and receiving unit and become unacceptably inaccurate as the wind fields become increasingly inhomogeneous due to their spatial and temporal averaging procedure (large measurement volume) that is inherent to the monostatic measurement principle. The new three-component fiber laser-based wind lidar sensor developed by the Physikalisch-Technische Bundesanstalt (PTB) uses one transmitting unit (fiber laser) and three receiving units to measure the velocity vector of single aerosols in a spatially highly resolved measurement volume (with diameter d and length l) in heights from 5 m (d= 300 μm, l= 2mm) to 250 m (d=14 mm, l=4 m) with a resolution of about 0.1 ms-1. Detailed comparison measurements with a 135 m high wind met mast and a conventional lidar system have proven that the high spatial and temporal resolution of the new, so-called bistatic lidar leads to a reduced measurement uncertainty compared to conventional lidar systems. Furthermore, the comparison demonstrates that the deviation between the bistatic lidar and the wind met mast lies well within the measurement uncertainty of the cup anemometers of the wind met mast for both homogeneous and inhomogeneous wind fields. At PTB, the aim is to use the bistatic wind lidar as a traceable reference standard to calibrate other remote sensing devices, necessitating an in-depth validation of the bistatic lidar system and its measurement uncertainty. To this end, a new, specially designed wind tunnel with a laser Doppler anemometer (LDA) as flow velocity reference has been erected on a platform at a height of 8 m; this allows the new wind lidar to be positioned below the wind tunnel test section to be validated for wind vector measurements that are traceable to the SI units. A first validation measurement within the wind tunnel test section is presented, showing a deviation between the bistatic lidar system and the LDA clearly below 0.1%.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License
Themenbereich der Metrologie Durchfluss
Förderinformationen (1) Förderername: Bundesministerium für Wirtschaft und Energie (BMWi)
Förderer ID: 0000 0001 1092 3392
Förderer ID Typ: ISNI
Titel der Förderung: PTB-Wind
Förderungsnummer: 0325945

Zitierung

Oertel, S., Eggert, M., Gutsmuths, C., Wilhelm, P., Müller, H., & Többen, H. (2019). Validation of three-component wind lidar sensor for traceable highly resolved wind vector measurements. Journal of Sensors and Sensor Systems, 9–17. https://doi.org/10.5194/jsss-8-9-2019

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag