| Titel | Towards mitigation of cable-loading effect with a cryocooled pulse-driven Josephson standard |
| Autor(in); Institution |
Sosso, Andrea; Istituto Nazionale di Ricerca Metrologica (INRIM), Torino, ITALY
Durandetto, Paolo; Istituto Nazionale di Ricerca Metrologica (INRIM), Torino, ITALY
Behr, Ralf; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Kieler, Oliver; 2.4, Quantenelektronik, PTB-Braunschweig
|
| Quelle/Jahr | 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018), Full Digest:(2018) |
| ISSN | 2160-0171 (ELECTRONIC) ; 0589-1485 (POD) |
| ISBN | 978-1-5386-0974-3 (PDF) ; 978-1-5386-0973-6 (USB) ; 978-1-5386-2130-1 (PoD) |
| DOI | |
| Verlag | Piscataway, NJ: IEEE |
| Konferenzangaben | Conference on Precision Electromagnetic Measurements ; CPEM 2018, Paris, 08-13, July, 2018, France |
| Freie Schlagworte | voltage standards ; pulse-driven Josephson arrays ; cable error reduction ; ac-dc transfer |
| Zusammenfassung | We present a cryocooler pulse-driven Josephson standard capable of significantly reducing the cable loading effect on a Josephson Arbitrary Waveform Standard, peculiar property of the setup is a very short stainless steel coax for the output connections. By means of an ac-dc transfer standard with an accurate determination of the frequency dependence, the residual cable load effect can be evaluated with low uncertainty. |
| Themenbereich der Metrologie | Elektrizität und Magnetismus |
| Forschungsprojekt | 15SIB04: QuADC: Waveform metrology based on spectrally pure Josephson voltages |
| Förderinformationen (1) |
Förderername: European Commission (EC)
Förderer ID: 0000 0001 2242 8989 Förderer ID Typ: ISNI Förderprogramm: EMPIR 2015 SI Broader Scope Titel der Förderung: 15SIB04: QuADC: Waveform metrology based on spectrally pure Josephson voltages Förderungsnummer: 15SIB04 |
Zitierung
Sosso, A., Durandetto, P., Behr, R., & Kieler, O. (2018). Towards mitigation of cable-loading effect with a cryocooled pulse-driven Josephson standard. Conference on Precision Electromagnetic Measurements ; CPEM 2018, Paris, 08-13, July, 2018, France. https://doi.org/10.1109/cpem.2018.8501217