Zugriffsnummer 40865
Dokumenttyp Zeitschriftenartikel
Peer Review mit Peer Review
Sprache Englisch
Titel Determination of kQ factors for cylindrical and plane-parallel ionization chambers in a scanned carbon ion beam by means of cross calibration
Autor(in); Institution
Krauss, Achim; 6.2, Dosimetrie für Strahlentherapie und Röntgendiagnostik, PTB-Braunschweig
Osinga-Blättermann, Julia-Maria; 6.2, Dosimetrie für Strahlentherapie und Röntgendiagnostik, PTB-Braunschweig
Quelle/Jahr Physics in Medicine and Biology: 64 (2018), 1 - 9
Artikelnummer 015009
ISSN 0031-9155 (PRINT) ; 1361-6560 (ONLINE)
DOI
Verlag Bristol: IOP Publishing
Freie Schlagworte kQ factor ; carbon ions ; cross calibration ; absorbed dose to water
Zusammenfassung The accuracy in the dosimetry of therapeutically used carbon beams is predominantly affected by the large uncertainty of the so-called kQ factor of the ionization chamber used for the measurements. Due to a lack of experimental data, the kQ factor of ionization chambers in carbon beams is still derived by calculation, and, for instance, a standard uncertainty of about 3% is given for kQ factors tabulated in the TRS-398 dosimetric protocol. Recently, kQ factors for two Farmer-type ionization chambers have been determined experimentally in the entrance channel of 429 MeV/u carbon ions, achieving about a threefold reduction of the uncertainty. To further improve the data basis on experimental kQ factors with low uncertainties, kQ factors for the same irradiation condition have now been determined for eight different cylindrical ionization chambers (NE2571, FC65-P, FC23-C, CC25, CC13, TM30010, TM30011, TM30012) and three different plane-parallel ionization chambers (PPC-40, PPC-05, TM34001) by means of a cross-calibration procedure. Generally, standard measurement uncertainties of 1.1% could be achieved. Deviations of less than 1.2% were found between the experimental and the tabulated kQ values. Moreover, the consideration of the experimental values with their smaller uncertainties in updated versions of the dosimetric protocols might enable a substantial reduction of the uncertainties in the dosimetry of carbon beams.
Themenbereich der Metrologie Ionisierende Strahlung

Zitierung

Krauss, A. & Osinga-Blättermann, J.-M. (2018). Determination of kQ factors for cylindrical and plane-parallel ionization chambers in a scanned carbon ion beam by means of cross calibration. Physics in Medicine and Biology, 64, 1–9. https://doi.org/10.1088/1361-6560/aaf5ac

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag