Zugriffsnummer 40366
Dokumenttyp Zeitschriftenartikel
Peer Review mit Peer Review
Sprache Englisch
Titel Electrostatic hazards during stirring of flammable organic solvents and suspensions in electrostatically portected plastic containers
Autor(in); Institution
Pidoll, Ulrich von; 3.7, Grundlagen des Explosionsschutzes, PTB-Braunschweig
Quelle/Jahr Journal of Electrostatics: 88 (2017), 197 - 200
ISSN 0304-3886
DOI
Verlag Amsterdam: Elsevier
Freie Schlagworte stirring ; liquids ; container ; IBC ; RIBC ; electrostatic charge ; hazards ; suspensions
Zusammenfassung At present, stirring of flammable liquids in rigid intermediate bulk containers (RIBCs) is allowed only if, firstly, the RIBC is electrostatically protected and secondly either a liquid such us water-based paint is used or the RIBC is inerted. To verify the necessity of these restrictions, several experimental setups were created to investigate the charging of stirred liquids and suspensions. The following questions were answered: 1) Which liquids/suspensions charge the most during stirring? 2) Is ethyl acetate a special charge accumulator? 3) Which safety measures are necessary for safe stirring in RIBCs?
Themenbereich der Metrologie Physikalische Sicherheitstechnik, Explosionsschutz

Zitierung

Pidoll, U. V. (2017). Electrostatic hazards during stirring of flammable organic solvents and suspensions in electrostatically portected plastic containers. Journal of Electrostatics, 88, 197–200. http://doi.org/10.1016/j.elstat.2016.11.005