Zugriffsnummer 39698
Dokumenttyp Zeitschriftenartikel
Peer Review unbekannt
Sprache Englisch
Titel Final report of the supplementary comparison EURAMET.EM-S31 : Comparison of capacitance and capacitance ratio
Autor(in); Institution
Schurr, Jürgen; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Fletcher, Nick; Bureau International des Poids et Mesures (BIPM), Sèvres, FRANCE
Gournay, Pierre; Bureau International des Poids et Mesures (BIPM), Sèvres, FRANCE
Thévenot, Olivier; Laboratoire National de Métrologie et d'Essais (LNE), Trappes, FRANCE
Overney, Frédéric; Federal Institute of Metrology (METAS), Bern-Wabern, SWITZERLAND
Leigh, Johnson; National Measurement Institute Australia (NMIA), Lindfield, AUSTRALIA
Xie, Raymond; National Measurement Institute Australia (NMIA), Lindfield, AUSTRALIA
Dierikx, Eric; VSL, Dutch Metrology Institute, Delft, THE NETHERLANDS
Quelle/Jahr Metrologia: 54 (2017), 1A, Tech. Suppl., 1 - 181
Artikelnummer 01016
Availability [online only]
ISSN 0026-1394
DOI
Verlag Bristol: IOP Publ.
Freie Schlagworte Inter-comparison ; capacitance standard ; ac-dc resistor ; quantum Hall resistance ; calculable capacitor ; von Klitzing constant
Zusammenfassung Within the framework of the Supplementary Comparison EURAMET.EM-S31, "Comparison of capacitance and capacitance ratio", five participants (the BIPM, METAS, LNE, PTB, and VSL) inter-compared their capacitance realisations traced to the quantum Hall resistance measured at either ac or dc. The measurands were the capacitance values of three 10 pF standards and one 100 pF standard, and optionally their voltage and frequency dependences. Because the results were not fully satisfying, the circulation was repeated, augmented by a link to the NMIA calculable capacitor. Also two ac-dc resistors were circulated and their frequency dependences were measured in terms of the ac-dc resistance standards involved in the particular capacitance realisations, to allow inter-comparison of these resistance standards. At the end and in any case, a good agreement is achieved within the expanded uncertainties at coverage factor k = 2. Furthermore, the comparison led to new insight regarding the stability and travelling behaviour of the capacitance standards and, by virtue of the link to the NMIA calculable capacitor, to a determination of the von Klitzing constant in agreement with the 2014 CODATA value.

Zitierung

Schurr, J., Fletcher, N., Gournay, P., Thévenot, O., Overney, F., Leigh, J., Xie, R., & Dierikx, E. (2017). Final report of the supplementary comparison EURAMET.EM-S31 : Comparison of capacitance and capacitance ratio. Metrologia, 54(1A, Tech. Suppl.), 1–181. https://doi.org/10.1088/0026-1394/54/1a/01016

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag