Zugriffsnummer 39409
Dokumenttyp Zeitschriftenartikel Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Improvement of the detection efficiency calibration and homogeneity measurement of Si-SPAD detectors
Autor(in); Institution
Dhoska, Klodian; Tallinn University of Technology, Tallinn, ESTONIA
Hofer, Helmuth; 4.1, Photometrie und angewandte Radiometrie, PTB-Braunschweig
Rodiek, Beatrice; 4.1, Photometrie und angewandte Radiometrie, PTB-Braunschweig
Lopez Ordonez, Marco Antonio; 4.1, Photometrie und angewandte Radiometrie, PTB-Braunschweig
Kübarsepp, Toomas; AS Metrosert, Tallinn, ESTONIA
Kück, Stefan; 4.1, Photometrie und angewandte Radiometrie, PTB-Braunschweig
Quelle/Jahr SpringerPlus: 5 (2016), 1 - 14
Artikelnummer 2065
Availability [online only]
ISSN 2193-1801
DOI
Verlag Springer
Freie Schlagworte Detection efficiency ; Si-SPAD detector ; Alignment ; Integrating sphere ; Homogeneity
Zusammenfassung Background: Silicon single-photon avalanche diodes (Si-SPADs) are the most used devices for measuring ultra-weak optical radiant fluxes in many quantum technology fields, such as quantum optics, quantum communication, quantum computing, etc. In all these fields, the detection efficiency is the main parameter, which has to be accurately known for achieving reliable measurements. In this paper we present the improvements performed on the setup described in López et al. (J Mod Opt 62:S21-S27, 2015) for determining the detection efficiency of Si-SPAD detectors with a low measurement uncertainty. The improvement arises from the precise alignment of the Si-SPAD detector and the low deviation reached between the total calculated filter transmission and the individual filter transmission measurements (≤0.05%) performed with an integrating sphere with attached Si-photodiode as standard detector. Results: The relative standard uncertainty of the Si-SPAD detection efficiency measurement achieved is now as low as ~0.16%. Furthermore, the investigation of the detection efficiency homogeneity of two commercial Si-SPAD detectors from different manufacturers and with different sensor diameters is also presented. The obtained homogeneity is ≤2.2% within a region of diameter of 40 μm. Conclusions: The detailed analysis presented in this paper shows the potential for achieving low measurement uncertainties for Si-SPAD detector calibration even in the low photon flux range. The low uncertainties are only to be realized for reproducible measurement conditions, i.e. in specific for equal beam sizes and beam shapes and well as for an irradiation of equal active areas of the detector. This, however, will be difficult to obtain when measurements are performed at different national metrology institutes.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 4.0 ; Creative Commons Attribution 4.0 License

Zitierung

Dhoska, K., Hofer, H., Rodiek, B., Lopez Ordonez, M. A., Kübarsepp, T., & Kück, S. (2016). Improvement of the detection efficiency calibration and homogeneity measurement of Si-SPAD detectors. SpringerPlus, 5, 1–14. https://doi.org/10.1186/s40064-016-3735-7

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag