Zugriffsnummer 39203
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Stray light characterization of Brewer MKII spectrophotometers
Autor(in); Institution
Pulli, Tomi; Metrology Research Institute, Aalto University, Espoo, FINLAND
Nevas, Saulius; 4.1, Photometrie und angewandte Radiometrie, PTB-Braunschweig
Kärhä, Petri; Metrology Research Institute, Aalto University, Espoo, FINLAND
Karppinen, Tomi; Finnish Meteorological Institute (FMI) - Arctic Research Centre, Sodankylä, FINLAND
Karhu, Juha M.; Finnish Meteorological Institute (FMI) - Arctic Research Centre, Sodankylä, FINLAND
Lakkala, Kaisa; Finnish Meteorological Institute (FMI) - Arctic Research Centre, Sodankylä, FINLAND
Vaskuri, Anna; Metrology Research Institute, Aalto University, Espoo, FINLAND
Shpak, Maksim; Metrology Research Institute, Aalto University, Espoo, FINLAND
Manoocheri, Farshid; Metrology Research Institute, Aalto University, Espoo, FINLAND
Doppler, Lionel; Deutscher Wetterdienst, Meteorologisches Observatorium Lindenberg - Richard Assmann Observatorium (DWD, MOL-RAO), Tauche, GERMANY
Gross, Steffen; Deutscher Wetterdienst, Meteorologisches Observatorium Lindenberg - Richard Assmann Observatorium (DWD, MOL-RAO), Tauche, GERMANY
Mes, Joop; Kipp & Zonen, Delft, THE NETHERLANDS
Ikonen, Erkki; Metrology Research Institute, Aalto University, Espoo, FINLAND
Quelle/Jahr 13th International Conference on New Developments and Applications in Optical Radiometry (NEWRAD 2017): Proceedings:(2017), 59 - 60
Availability [USB-Stick]
Verlag [s.l.]:
Konferenzangaben NEWRAD 2017, Tokyo, 13-16, June, 2017, Japan
Zusammenfassung The results of single- and double-monochromator Brewer spectrophotometers differ from each other especially at short solar UV wavelengths even after in-range stray light correction. To investigate whether an out-of-range stray light contribution in single monochromator instruments could be the cause, two Brewer MKII instruments and a set of bandpass filters typically used in the instruments were characterized. It was concluded that out-ofrange stray light is of minor concern for these instruments, and the differences are instead likely caused by residual errors of stray light correction in the pass- and transition bands.

Zitierung

Pulli, T., Nevas, S., Kärhä, P., Karppinen, T., Karhu, J. M., Lakkala, K., Vaskuri, A., Shpak, M., Manoocheri, F., Doppler, L., Gross, S., Mes, J., & Ikonen, E. (2017). Stray light characterization of Brewer MKII spectrophotometers. NEWRAD 2017, Tokyo, 13-16, June, 2017, Japan.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag