Zugriffsnummer 38423
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Three-component laser Doppler anemometer for gas flowrate measurements up to 5 500 m3/h
Autor(in); Institution
Dopheide, Dietrich; 1.31, Strömungsmesstechnik, PTB-Braunschweig
Strunck, Volker; 1.31, Strömungsmesstechnik, PTB-Braunschweig
Krey, Ernst-August; 1.31, Strömungsmesstechnik, PTB-Braunschweig
Quelle/Jahr Metrologia: 30 (1993), 5, 453 - 469
ISSN 0026-1394
DOI
Verlag Bristol: IOP Publ.
Zusammenfassung In the Physikalisch-Technische Bundesanstalt (PTB) the primary standard for on-line flowrate measurements using the laser Doppler anemometer (LDA) technique has been extended to a three-component LDA to improve velocity profile measurements in the boundary layers of a nozzle flow. The LDA flowrate measuring facility now consists of a two-colour argon ion LDA and a wavelength-stabilized GaAlAs diode laser LDA. the gas flowrate is obtained by numerical integration of the measured velocity profiles across the exit plane of the nozzle. High local resolution of the velocity profile measurements is achieved by perpendicular orientation of the measurement volumes of the two-component gas laser LDA and the semiconductor diode laser LDA (LD-LDA). This allows the resolution in the boundary layer to be improved significantly to velocity gradients. The present work presents the LD-LDA system for precise velocity profile measurements at flow velocities of up to 120 m/s; selected profile measurements are described in detail to demonstrate the high resolution and the symmetry of the flow profile. For the first time an wavelength-stabilized miniaturized diode laser LDA has been successfully applied in precise velocity measurements, and comparisons with well-established gas laser LDAs have been made. The uncertainty of the flowrate measurement up to 5 500 m3/h is 0,1 % for air at atmospheric pressure. A turbine gas meter, type Elster G2500, was calibrated with the LDA and used as a transfer standard for an intercomparison with the Nederlands Meetinstituut (NMI) in the flowrate range up to 5 500 m3/h with and without the installation of perforated plates to condition the flow in the inlet section og the gas meter. The results of the comparison experiment clearly show the reliability and accuracy of the on-line flowrate measurement of gases and underline the necessity for a detailed research programme to investigate the relationship between installation effects, upstream flow conditions and the measurement uncertainty of gas meters. The design of a test rig now under construdtion at the PTB is shown. This will allow the diode laser LDA technique to be applied to the measurement of installation effects according to OIML Recommendation R-32.

Zitierung

Dopheide, D., Strunck, V., & Krey, E.-A. (1993). Three-component laser Doppler anemometer for gas flowrate measurements up to 5 500 m³/h. Metrologia, 30(5), 453–469. https://doi.org/10.1088/0026-1394/30/5/001

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag