| Zugriffsnummer | 37331 |
| Dokumenttyp | Konferenzartikel |
| Sprache | Englisch |
| Titel | Carrier-phase two-way satellite frequency transfer between LNE-SYRTE and PTB |
| Autor(in); Institution |
Fujieda, Miho; National Institute of Information and Communications Technology, Tokyo, JAPAN
Takiguchi, Hiroshi; National Institute of Information and Communications Technology, Tokyo, JAPAN
Achkar, Joseph; PSL Research University, Observatoire de Paris, LNE-SYRTE, Paris, FRANCE; CNRS, Paris, FRANCE; Sorbonne Universités, UPMC Université Pierre et Marie Curie Paris 06, Paris, FRANCE
Abgrall, Michel; PSL Research University, Observatoire de Paris, LNE-SYRTE, Paris, FRANCE; CNRS, Paris, FRANCE; Sorbonne Universités, UPMC Université Pierre et Marie Curie Paris 06, Paris, FRANCE
Guena, Jocelyne; PSL Research University, Observatoire de Paris, LNE-SYRTE, Paris, FRANCE; CNRS, Paris, FRANCE; Sorbonne Universités, UPMC Université Pierre et Marie Curie Paris 06, Paris, FRANCE
Riedel, Franziska; 4.4, Zeit und Frequenz, PTB-Braunschweig
Benkler, Erik; 4.4, Zeit und Frequenz, PTB-Braunschweig
Weyers, Stefan; 4.4, Zeit und Frequenz, PTB-Braunschweig
Piester, Dirk; 4.4, Zeit und Frequenz, PTB-Braunschweig
|
| Quelle/Jahr | 2016 European Frequency and Time Forum (EFTF):(2016), 1 - 4 |
| ISBN | 978-1-5090-0720-2 |
| DOI | |
| Verlag | IEEE |
| Konferenzangaben | European Frequency and Time Forum (EFTF) 2016, York, 04-07, April, 2016, UK |
| Freie Schlagworte | atomic fountain frequency standard ; carrier-phase ; TWSTFT |
| Zusammenfassung | We performed a carrier-phase two-way satellite frequency transfer (TWCP) experiment between LNE-SYRTE and PTB for several days in September 2015. Different hardware configurations were analyzed at the LNE-SYRTE earth station and a suitable configuration was identified by placing up- and down-converters indoors. Additionally atomic fountain frequency standards were operated simultaneously at both institutes. This offered a comparison of two reference clocks at LNE-SYRTE and PTB independently by means of TWCP and via the fountain clocks. Even with a very limited and not continuous measurement time of about 8 hours for TWCP measurements, a frequency transfer uncertainty below 2×10-15 was achieved and the results by the fountain clocks and TWCP agreed well within this uncertainty. |
Zitierung
Fujieda, M., Takiguchi, H., Achkar, J., Abgrall, M., Guena, J., Riedel, F., Benkler, E., Weyers, S., & Piester, D. (2016). Carrier-phase two-way satellite frequency transfer between LNE-SYRTE and PTB. European Frequency and Time Forum (EFTF) 2016, York, 04-07, April, 2016, UK. https://doi.org/10.1109/eftf.2016.7477798