Zugriffsnummer 37331
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Carrier-phase two-way satellite frequency transfer between LNE-SYRTE and PTB
Autor(in); Institution
Fujieda, Miho; National Institute of Information and Communications Technology, Tokyo, JAPAN
Takiguchi, Hiroshi; National Institute of Information and Communications Technology, Tokyo, JAPAN
Achkar, Joseph; PSL Research University, Observatoire de Paris, LNE-SYRTE, Paris, FRANCE; CNRS, Paris, FRANCE; Sorbonne Universités, UPMC Université Pierre et Marie Curie Paris 06, Paris, FRANCE
Abgrall, Michel; PSL Research University, Observatoire de Paris, LNE-SYRTE, Paris, FRANCE; CNRS, Paris, FRANCE; Sorbonne Universités, UPMC Université Pierre et Marie Curie Paris 06, Paris, FRANCE
Guena, Jocelyne; PSL Research University, Observatoire de Paris, LNE-SYRTE, Paris, FRANCE; CNRS, Paris, FRANCE; Sorbonne Universités, UPMC Université Pierre et Marie Curie Paris 06, Paris, FRANCE
Riedel, Franziska; 4.4, Zeit und Frequenz, PTB-Braunschweig
Benkler, Erik; 4.4, Zeit und Frequenz, PTB-Braunschweig
Weyers, Stefan; 4.4, Zeit und Frequenz, PTB-Braunschweig
Piester, Dirk; 4.4, Zeit und Frequenz, PTB-Braunschweig
Quelle/Jahr 2016 European Frequency and Time Forum (EFTF):(2016), 1 - 4
ISBN 978-1-5090-0720-2
DOI
Verlag IEEE
Konferenzangaben European Frequency and Time Forum (EFTF) 2016, York, 04-07, April, 2016, UK
Freie Schlagworte atomic fountain frequency standard ; carrier-phase ; TWSTFT
Zusammenfassung We performed a carrier-phase two-way satellite frequency transfer (TWCP) experiment between LNE-SYRTE and PTB for several days in September 2015. Different hardware configurations were analyzed at the LNE-SYRTE earth station and a suitable configuration was identified by placing up- and down-converters indoors. Additionally atomic fountain frequency standards were operated simultaneously at both institutes. This offered a comparison of two reference clocks at LNE-SYRTE and PTB independently by means of TWCP and via the fountain clocks. Even with a very limited and not continuous measurement time of about 8 hours for TWCP measurements, a frequency transfer uncertainty below 2×10-15 was achieved and the results by the fountain clocks and TWCP agreed well within this uncertainty.

Zitierung

Fujieda, M., Takiguchi, H., Achkar, J., Abgrall, M., Guena, J., Riedel, F., Benkler, E., Weyers, S., & Piester, D. (2016). Carrier-phase two-way satellite frequency transfer between LNE-SYRTE and PTB. European Frequency and Time Forum (EFTF) 2016, York, 04-07, April, 2016, UK. https://doi.org/10.1109/eftf.2016.7477798