Zugriffsnummer 36765
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Detailing local multi-channel RF surface coil versus body RF coil transmission for cardiac MRI at 3 Tesla: which configuration is winning the game?
Autor(in); Institution
Weinberger, O.; Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Centrum für Molekulare Medizin (MDC), Berlin, GERMANY
Winter, L.; Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Centrum für Molekulare Medizin (MDC), Berlin, GERMANY
Dieringer, M; Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Centrum für Molekulare Medizin (MDC), Berlin, GERMANY
Els, A.; Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Centrum für Molekulare Medizin (MDC), Berlin, GERMANY
Oezerdem, c:; Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Centrum für Molekulare Medizin (MDC), Berlin, GERMANY
Rieger, J.; MRI.TOOLS GmbH, Berlin, GERMANY
Kühne, A.; MRI.TOOLS GmbH, Berlin, Germany
Cassara, A.; 8.1, Medizinische Messtechnik, PTB-Berlin
Pfeiffer, Harald; 8.1, Medizinische Messtechnik, PTB-Berlin
Niendorf, T.; Berlin Ultrahigh Field Facility (BUFF), Max Delbrück Centrum für Molekulare Medizin (MDC), Berlin, GERMANY
Quelle/Jahr 7rd Annual Scientific Symposium Ultrahigh Field Magnetic Resonance:(2016), 4 S.
Verlag Berlin:
Konferenzangaben 7rd Annual Scientific Symposium Ultrahigh Field Magnetic Resonance: Clinical Needs, Research Promises and Technical Solutions, Berlin-Buch, Berlin, 24, June, 2016, Germany
Zusammenfassung In current clinical cardiac MR (CMR) integrated body RF coils are commonly used for 1H excitation, which deposit the RF energy/SAR in a large volume of the patient/subject.Progress in ultrahigh field MR (B0≥7T), where body RF coils are not provided, demonstrated that local transceiver (TX/RX) RF coil arrays are suitable for RF excitation of deep lying regions such as the heart.Recognizing this opportunity, this work demonstrates the feasibility of CMR at 3T with a local four-channel TX/RX RF coil array. This setup is benchmarked against the clinical standard of a body RF coil for excitation in conjunction with a four-channel RX-only RF coil.Our assessment includes electromagnetic field (EMF) simulations to detail SAR and B1+-homogeneity and -efficiency for the local and body RF coil configuration and their in vivo performance for high spatial resolution 2D SSFP-CINE imaging of the heart.

Zitierung

Weinberger, O., Winter, L., Dieringer, M., Els, A., Oezerdem, C., Rieger, J., Kühne, A., Cassara, A., Pfeiffer, H., & Niendorf, T. (2016). Detailing local multi-channel RF surface coil versus body RF coil transmission for cardiac MRI at 3 Tesla: which configuration is winning the game? 7rd Annual Scientific Symposium Ultrahigh Field Magnetic Resonance: Clinical Needs, Research Promises and Technical Solutions, Berlin-Buch, Berlin, 24, June, 2016, Germany.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag