Titel Accuracy of the new voltage standard using Josephson junctions cooled to 77 K
Autor(in); Institution
Khorshev, S. K.; Institute of Electronic Measurements (KVARZ), Nizhny Novgorod, RUSSIA
Pashkovsky, A. I.; Institute of Electronic Measurements (KVARZ), Nizhny Novgorod, RUSSIA
Rogozhkina, N. V.; Institute of Electronic Measurements (KVARZ), Nizhny Novgorod, RUSSIA
Levichev, M. Yu.; Russian Academy of Sciences, Institute for Physics of Microstructures, Nizhny Novgorod, RUSSIA
Pestov, E. E.; Russian Academy of Sciences, Institute for Physics of Microstructures, Nizhny Novgorod, RUSSIA
Katkov, A. S.; Mendeleyev Institute for Metrology (VNIIM), St. Petersburg, RUSSIA
Behr, Ralf; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Kohlmann, Johannes; 2.4, Quantenelektronik, PTB-Braunschweig
Klushin, A. M.; Russian Academy of Sciences, Institute for Physics of Microstructures, Nizhny Novgorod, RUSSIA; Institute of Electronic Measurements (KVARZ), Nizhny Novgorod, RUSSIA
Quelle/Jahr CPEM 2016, Conference on Precision Electromagnetic Measurements: conference digest:(2016), 2 S.
Availability [USB-Stick] ; file name: 255.pdf
ISBN 978-1-4673-9134-4 ; 978-1-4673-9133-7
DOI
Verlag [s.l.]: IEEE
Konferenzangaben Conference on Precision Electromagnetic Measurements (CPEM) 2016, Ottawa, 10-15, July, 2016, Canada
Freie Schlagworte High-temperature superconductors ; Josephson array ; precision measurements ; uncertainty ; voltage standard
Zusammenfassung A practical dc voltage standard with output voltages UHTS from 0.1 V to 10 V using high temperature superconductor (HTS) arrays of Josephson junctions cooled to 77 K was characterized. HTS arrays with increased current margins and the voltage divider with a high stability of the divider’s coefficients enable stable and reproducible automated calibration of the new HTS standard. The direct comparison of U.Sub.HTS against the voltage generated on an array of niobium Josephson junctions cooled to 4.2 K reveals the agreement of voltages at 1 V level with a Type A uncertainty equal to a few parts in 108.

Zitierung

Khorshev, S. K., Pashkovsky, A. I., Rogozhkina, N. V., Levichev, M. Y., Pestov, E. E., Katkov, A. S., Behr, R., Kohlmann, J., & Klushin, A. M. (2016). Accuracy of the new voltage standard using Josephson junctions cooled to 77 K. Conference on Precision Electromagnetic Measurements (CPEM) 2016, Ottawa, 10-15, July, 2016, Canada. https://doi.org/10.1109/cpem.2016.7540701