Zugriffsnummer 35938
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Potential reference measurement procedures for PBDE in surface water at levels required by the EU Water Frame Directive.
Autor(in); Institution
Swart, Claudia; 3.1, Metrologie in der Chemie, PTB-Braunschweig
Gantois, Fanny; Laboratoire national de metrologie et d’essais (LNE), Paris, FRANCE
Petrov, Panayot; LGC Limited (LGC), Teddington, UK
Entwisle, John; LGC Limited (LGC), Teddington, UK
Goenaga-Infante, Heidi; LGC Limited (LGC), Teddington, UK
Nousiainen, Marjaana; Finish Environment Institute (SYKE), Helsinki, FINLAND
Bílsel, Mine; TÜB\İTAK Ulusal Metroloji Enstitusu (TÜB\İTAK UME), Gebze, Kocaeli, TURKEY
Binici, Burcu; TÜB\İTAK Ulusal Metroloji Enstitusu (TÜB\İTAK UME), Gebze, Kocaeli, TURKEY
Gonzalez-Gago, Adriana; Helmholtz-Zentrum Geesthacht (HZG), Geesthacht, GERMANY
Pröfrock, Daniel; Helmholtz-Zentrum Geesthacht (HZG), Geesthacht, GERMANY
Gören, Ahmet C.; TÜB\İTAK Ulusal Metroloji Enstitusu (TÜB\İTAK UME), Gebze, Kocaeli, TURKEY
Quelle/Jahr Talanta: 152 (2016), 251 - 258
ISSN 0039-9140 (PRINT) ; 1873-3573 (ONLINE)
DOI
Verlag Amsterdam [u.a.]: Elsevier Science
Freie Schlagworte PBDE ; water frame directive ; water ; method validation ; IDMS
Zusammenfassung Polybrominated diphenylethers (PBDE), used as flame retardants, are named as priority substances in the Directive 2000/60/EC of the European parliament and of the council establishing a framework for Community action in the field of water policy. An annual average environmental quality standard (EQS) for inland surface waters of 0.0005 µg/L (0.0002 µg/L for other surface waters) for PBDE congeners involved in the technical penta-PBDE mixtures containing PBDE with five bromine atoms has been established. The directives focus especially on the congeners PBDE 28, 47, 99, 100, 153 and 154 contained in the penta-PBDE mixture. Up to now, no reference measurement procedures have been established reaching the limits of quantification (LOQs) and the associated uncertainties as defined in the directives with results traceable to the SI. Within a recent European project on metrology, different approaches for the traceable quantification of PBDE, based on liquid/liquid or solid phase extraction followed by the detection with gas chromatography coupled to either inductively coupled plasma mass spectrometry or triple quadrupole mass spectrometry, were investigated and the related LOQs and expanded uncertainties of the results were compared. A complete uncertainty budget for each method was estimated according to the Guide to the Expression of Uncertainty in Measurement (GUM). All presented analytical procedures can serve as reference measurement procedures regarding the LOQs and their associated expanded uncertainties for monitoring the six priority PBDEs named above. LOQs as low as 0.026 ng/kg with an associated expanded uncertainty of 0.002 ng/kg could be achieved.

Zitierung

Swart, C., Gantois, F., Petrov, P., Entwisle, J., Goenaga-Infante, H., Nousiainen, M., Bílsel, M., Binici, B., Gonzalez-Gago, A., Pröfrock, D., & Gören, A. C. (2016). Potential reference measurement procedures for PBDE in surface water at levels required by the EU Water Frame Directive. Talanta, 152, 251–258. https://doi.org/10.1016/j.talanta.2016.01.066

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag